| 전자부품 데이터시트 검색엔진 |
|
ADMV8502ACCZ-R7 데이터시트(PDF) 14 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADMV8502ACCZ-R7 데이터시트(HTML) 14 Page - Analog Devices |
|
14 / 32 page ![]() Data Sheet ADMV8502 THEORY OF OPERATION analog.com Rev. 0 | 14 of 32 INTERPOLATION PLOTS To garner a visual representation of the interpolation functions, the interpolation coefficients vs. their input (from the interpolation tables) can be plotted on a scatter plot. Figure 23, Figure 24, and Figure 25 are the interpolation functions of y, v, and t using the interpolation coefficients. Figure 23. Interpolation Function of y = f(x) Figure 24. Interpolation Function of v = f(y) Figure 25. Interpolation Function of t = f(y) INTERPOLATION COEFFICIENT CALIBRATION Two primary reasons for the need to calibrate the interpolation coefficients include accounting for chip process variation and when a different operating bandwidth is required. The calibration of inter- polation coefficients normally follows a four phase process (see Figure 27). In the first calibration phase, the bandwidth and match coefficients, V1 and T1, are determined for a desired bandwidth. To perform this calibration phase, the fCENTER load value must be set to 32, and then the bandwidth and match load values are adjusted. When satisfied with the results, the V1 and T1 coefficients can be set to the bandwidth and match load values, respectively. For the second calibration phase, the bandwidth and match coeffi- cients, V2 and T2, are determined for a desired bandwidth. To perform this calibration phase, the fCENTER load value must be set to a high value (180 is recommended), and then the bandwidth and match load values are adjusted. When satisfied with the results, the V2 coefficient can be adjusted so that the computed result of v = f(y) = f(180) is equal to the bandwidth load value. Similarly, the T2 coefficient can be adjusted so that the computed result of t = f(y) = f(180) is equal to the match load value. For the third calibration phase, the bandwidth and match coeffi- cients, V0 and T0, are determined for a desired bandwidth. To perform this calibration phase, the fCENTER load value must be set to a low value (18 is recommended), and then the bandwidth and match load values are adjusted. When satisfied with the results, the V0 coefficient can be adjusted so that the computed result of v = f(y) = f(18) is equal to the bandwidth load value. Similarly, the T0 coefficient can be adjusted so that the computed result of t = f(y) = f(18) is equal to the match load value. For the fourth calibration phase, adjustments are made to all of the y coefficients to ensure the operating fCENTER is as close as possi- ble to the anticipated fCENTER. To perform this calibration phase, use Table 9 as a reference for determining the target frequency for each y coefficient. For each x value listed in Table 9, compute the y, v, |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |