| 전자부품 데이터시트 검색엔진 |
|
AS621X 데이터시트(PDF) 18 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
AS621X 데이터시트(HTML) 18 Page - OSRAM GmbH |
|
18 / 37 page ![]() Document Feedback AS621x Register Description Datasheet • PUBLIC DS000677 • v4-00 • 2022-May-17 36 │ 17 6.2.7 Consecutive Faults A fault condition persists if the measured temperature either exceeds the configured value in register THIGH or falls below the defined value in register TLOW. As a result, the ALERT pin indicates the fault condition if a defined number of consecutive temperature readings meets this fault condition. The number of consecutive faults are defined with two bits (12 and 11) and prevent a false alert if environmental temperature noise is present. The register configuration is shown in the following table. Figure 21: Consecutive Faults Bit Settings Consecutive Fault Bits Consecutive Faults (N) Bit 13 Bit 12 0 0 1 0 1 2 1 0 3 1 1 4 6.2.8 Single Shot Conversion The device features a single shot measurement mode if the device is in sleep mode (SM=1). By setting th e “Single Shot-bit” to 1, a single temperature conversion is started and the SS-bit can be read as 1 during the active conversion operation. Once the conversion is completed, the device enters the sleep mode again and the SS-bit is set to 0. The single shot conversion allows very low power consumption since a temperature conversion is executed on demand only. This allows a user defined timing of the temperature conversions to be executed and is used if the consecutive operation mode is not required. The first conversion triggered in this mode has a longer conversion time. In the section 6.2.4 Sleep Mode it is detailed together with the recommendation to trigger the first conversion simultaneously with entering the sleep mode. As the device exhibits a very short conversion time, the effective conversion rate can be increased by setting the single shot bit repetitively after a conversion has finished. However, it has to be ensured that the additional power is limited, otherwise self-heating effects have to be considered. Figure 22: Single Shot Conversion Bit Settings Single Shot Bit Conversion 0 No conversion ongoing/ conversion finished 1 Start single shot conversion / conversion ongoing |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |