AS6221T-AWLM 데이터시트(PDF) 27 Page - OSRAM GmbH

부품명 AS6221T-AWLM
상세설명  Digital temperature sensor
PDF  36 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  OSRAM [OSRAM GmbH]
홈페이지  http://www.osram.com
Logo OSRAM - OSRAM GmbH

AS6221T-AWLM 데이터시트(HTML) 27 Page - OSRAM GmbH

Back Button AS6221T-AWLM Datasheet HTML 23Page - OSRAM GmbH AS6221T-AWLM Datasheet HTML 24Page - OSRAM GmbH AS6221T-AWLM Datasheet HTML 25Page - OSRAM GmbH AS6221T-AWLM Datasheet HTML 26Page - OSRAM GmbH AS6221T-AWLM Datasheet HTML 27Page - OSRAM GmbH AS6221T-AWLM Datasheet HTML 28Page - OSRAM GmbH AS6221T-AWLM Datasheet HTML 29Page - OSRAM GmbH AS6221T-AWLM Datasheet HTML 30Page - OSRAM GmbH AS6221T-AWLM Datasheet HTML 31Page - OSRAM GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 27 / 36 page
background image
AS6221T
Register description
Datasheet
• PUBLIC • Document Feedback
DS001032
• v3-00 • 2023-Oct-13
27 / 36
/
pulled to low level. The slave remains inactive after a timeout and waits for a new START
command invoked by the bus master. In order to prevent a timeout, the bus transfer rate must
be higher than 1 kHz.
6.3.13
Bus conditions
The following conditions occur on the serial bus which is compatible to the I²C-Bus.
Bus idle
The signals SDA and SCL are not actively driven and pulled to a high level by an external pull-
up resistor.
Start data transfer
A transition of the SDA input from high to low level while the SCL signal is kept at high level
results in a START condition. Such a START condition must precede any data transfer.
Stop data transfer
A transition of the SDA input from low to high level while the SCL signal is kept at high level
results in a STOP condition. Any data transfer is finished by generating a STOP or START
condition.
Data transfer
The master device defines the number of data bytes between a START and STOP condition
and there is no limitation in the amount of data to be transmitted.
If it is desired to read only a single MSB byte without the LSB byte, a termination of the data
transfer can be provoked by issuing a START or STOP condition on the bus.
Acknowledge
It is mandatory for each slave device to respond with acknowledge if the device is addressed
by the master. Acknowledge is indicated by pulling down the data line (SDA) while the clock
signal (SCL) is high in the acknowledge clock phase. In order to avoid an unwanted START or
STOP condition on the bus, setup and hold times must be met.
The master can signal an end of data transmission by transmitting a Not-Acknowledge on the
last transmitted data byte by keeping the acknowledge bit at high level.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com