  SP7680EB Datasheet HTML 1Page - Sipex Corporation SP7680EB Datasheet HTML 2Page - Sipex Corporation SP7680EB Datasheet HTML 3Page - Sipex Corporation SP7680EB Datasheet HTML 4Page - Sipex Corporation SP7680EB Datasheet HTML 5Page - Sipex Corporation SP7680EB Datasheet HTML 6Page - Sipex Corporation SP7680EB Datasheet HTML 7Page - Sipex Corporation SP7680EB Datasheet HTML 8Page - Sipex Corporation SP7680EB Datasheet HTML 9Page - Sipex Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 16 page
background image
June 21-07 revH
SP7680: Complete Backlight Solution
2007 Sipex Corporation
Page 4
TIMING CHARACTERISTICS
Note 3: Power-up time from Shutdown
START
ADDRESS A
STATUS
A
CNTRL
A
MAIN
A
SUB
A
AUX
A
STOP
I
2C data input
5%
Power-up time (Softstart time)
VOUT
Drivers ON
IOUT
1x mode
1.5x mode
1x mode
Note 4: Soft Start Interval (within 1x Mode)
START
ADDRESS A
STATUS
A
CNTRL
A
MAIN
A
SUB
A
AUX
A
STOP
I
2C data input (Final state)
Soft Start Interval within 1X mode
The softstart interval within 1x mode:
After mode changes from Standby to Active, the time from the rising edge of
“STATUS” acknowledge bit to the point where the ILED is within 5% of its final value at full load. This softstart is
tested with VIN = 4.0V to ensure 1x mode.
5%
Output Current within
5% of final value
ILED
Note 5: Soft Start Interval (Transition 1x to 1.5x Mode)
START
ADDRESS A
STATUS
A
CNTRL
A
MAIN
A
SUB
A
AUX
A
STOP
I2C data input (Final state)
Soft Start Interval within 1.5X mode
The softstart interval from 1x to 1.5x mode: After mode changing from 1x mode to 1.5x mode, the time from the
rising edge of “CNTRL” acknowledge bit to the point where VOUT is within 5% of its final value at full load. This is
the measurement to know the boosting time of the charge pump at full load current. In this case, it is easier to
measure VOUT than IOUT. Softstart is tested with VIN = 3.4V to force a mode transition.
5%
Mode of charge pump changes from
1x mode to 1.5x mode at the full load.
VOUT
1x mode
1.5x mode



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com