| 전자부품 데이터시트 검색엔진 |
|
LMP91200MT/NOPB 데이터시트(PDF) 15 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
LMP91200MT/NOPB 데이터시트(HTML) 15 Page - Texas Instruments |
|
15 / 25 page ![]() LMP91200 + ± pH BUFFER VCM BUFFER VDD VDD GND GND MCU VOUT ADC VOCM VREF GND VCMHI NC NC GUARD1 GUARD2 INP VCM GND pH Electrode 15 LMP91200 www.ti.com SNAS571E – JANUARY 2012 – REVISED FEBRUARY 2016 Product Folder Links: LMP91200 Submit Documentation Feedback Copyright © 2012–2016, Texas Instruments Incorporated 8 Application and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 8.1 Application Information 8.1.1 Theory of pH Measurement The pH electrode measurements are made by comparing the readings in a sample with the readings in standards whose pH has been defined (buffers). When a pH sensing electrode comes in contact with a sample, a potential develops across the sensing membrane surface and that membrane potential varies with pH. A reference electrode provides a second, unvarying potential to quantitatively compare the changes of the sensing membrane potential. These days, pH electrodes are composed of a sensing electrode with the reference electrode built into the same electrode body, and they are called combination electrodes. A high input impedance meter serves as the readout device and calculates the difference between the reference electrode and sensing electrode potentials in millivolts. The millivolts are then converted to pH units according to the Nernst equation. Electrode behavior is described by the Nernst equation: E = Eo + (2.3 RT/nF) log aH+ where • E is the measured potential from the sensing electrode, • Eo is related to the potential of the reference electrode, • (2.3 RT/nF) is the Nernst factor, • log aH+ is the pH, (aH+ = activity of Hydrogen ions). (1) 2.3 RT/nF includes the Gas Law constant (R), Faraday’s constant (F), the temperature in degrees Kelvin (T) and the stoichiometric number of ions involved in the process (n). For pH, where n = 1, the Nernst factor is 2.3 RT/F. Because R and F are constants, the factor and therefore electrode behavior is dependent on temperature. The Nernst Factor is equivalent to the electrode slope which is a measure of the electrode response to the ion being detected. When the temperature is 25°C, the theoretical Nernst slope is 59.16 mV/pH unit. 8.2 Typical Application Figure 34. Typical Application |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |