Back Button MB89R119B Datasheet HTML 3Page - RAMXEED LIMITED MB89R119B Datasheet HTML 4Page - RAMXEED LIMITED MB89R119B Datasheet HTML 5Page - RAMXEED LIMITED MB89R119B Datasheet HTML 6Page - RAMXEED LIMITED MB89R119B Datasheet HTML 7Page - RAMXEED LIMITED MB89R119B Datasheet HTML 8Page - RAMXEED LIMITED MB89R119B Datasheet HTML 9Page - RAMXEED LIMITED MB89R119B Datasheet HTML 10Page - RAMXEED LIMITED MB89R119B Datasheet HTML 11Page - RAMXEED LIMITED Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 46 page
background image
MB89R119B
DS411-00002-4v0-E
7
4. Cyclic Redundancy Check (CRC)
Upon reception of a request from the reader/writer, the transponder shall verify that CRC value is valid. If it
is invalid, it shall discard the frame and shall not answer.
Upon reception of a response from the transponder, the reader/writer is recommended that the reader/writer
verify that the CRC value is valid. If it is invalid, actions to be performed are left to the responsibility of the
reader/writer maker. For error-checking, the 2 bytes CRC are appended to each request and each response,
with each frame, before the EOF.
The CRC is calculated on all the bytes after the SOF up to but not including the CRC field. Method of
calculation is provided in ISO/IEC 13239 and the detail is defined in ISO/IEC 15693-3 and ISO/IEC 18000-
3 (Mode 1) . The initial value of the CRC code provided in ISO/IEC 15693-3 is “FFFFH”.
The CRC code is transferred, beginning with the least significant bit in the least significant byte.
5. Electronic Article Surveillance (EAS) status
EAS status is 1 bit data, which is stored in the system area of memory (FeRAM) . The initial value is “1”.
EAS bit “1” means goods-monitoring status, and EAS bit “0” means that goods-monitoring status is cleared.
EAS status can be written by Write EAS command and can be checked “3DH” block (refer to “ MEMORY
MAP) by Read commands such as Read Signal Block command.
Together with Gate type reader/writer, EAS command can support anti-theft security functions.
CRC bit/bytes transmission rules
LSByte
MSByte
LSBit
MSBit LSBit
MSBit
CRC 16 (8 Bits)
CRC 16 (8 Bits)
First transmitted bit of the CRC



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com