| 전자부품 데이터시트 검색엔진 |
|
L5963 데이터시트(PDF) 32 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L5963 데이터시트(HTML) 32 Page - STMicroelectronics |
|
32 / 49 page ![]() Application information L5963 32/49 DocID028553 Rev 3 Figure 14. Closed loop system with TYPE III network The above figure shows the closed loop system with a TYPE III compensation network and presents the closed loop transfer function. See the guidelines for calculation of TYPE III network below: 1. Choose a value for R1, usually between 2 k and 5 kΩ. 2. Choose a gain (R2/R1) that shifts the Open Loop Gain up to give the desired bandwidth. This allows the 0 dB crossover to occur in the frequency range where the Type III network has its second plateau in the gain. The following equation calculates an R2 that accomplishes this, given the system parameters and a chosen R1. Equation 9 3. C2 is calculated by placing the zero at 50% of the output filter double pole frequency: Equation 10 4. C1 can be calculated by placing the first pole at the ESR zero frequency: Equation 11 5. Set the second pole at half the switching frequency and also set the second zero at the output filter double pole. This combination brings the following equation: |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|