74 / 178 page ![]() 12.3 GPO error handling Table 48. GPO error handling Type of error Detection condition Action Clear SPI flag Restart condition GPO Overcurrent On state, LS on GPO output switched-off and SPI GPO OVC fault bit (13) latched in SERVFLT register On read Automatic on SPI read Open load (OPL) On state, LS configuration, LS off, diagnostic enabled Set SPI GPO OL (14) fault bit in SERVFLT register On read N.A. Short to GND (STG) On state, LS configuration, LS off Set SPI GPO STG (12) fault bit in SERVFLT register On read N.A. L9300 General purpose output (GPO) DS12258 - Rev 5 page 74/178 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|