| 전자부품 데이터시트 검색엔진 |
|
PAC1933T-I/JQ. 데이터시트(PDF) 46 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PAC1933T-I/JQ. 데이터시트(HTML) 46 Page - Microchip Technology |
|
46 / 62 page ![]() PAC1932/3/4 DS20005850C-page 46 2017-2018 Microchip Technology Inc. REGISTER 6-15: CTRL_ACT REGISTER (ADDRESS 21H) R-0R-0 R-0R-0 R-0R-0 R-0R-0 Sample_Rate<1:0> SLEEP SING ALERT_PIN ALERT_CC OVF ALERT OVF bit 7 bit 0 Legend: R = Readable bit W = Writeable bit U = Unimplemented bit, read as ‘0’ -n = Value at POR ‘1’ = bit is set ‘0’ = Bit is cleared x = Bit is unknown This register contains an image of the Control register, 01h. The bits in this register reflect the current active value of these settings, whereas the values in register 01h may have been programmed but not activated by one of the REFRESH commands. This register allows the software to determine the actual active setting. This register is valid when the Results registers are valid, 1 ms after a REFRESH/_V/_G command (in most cases). However, if the users program a conversion rate change followed by REFRESH, the new conversion rate will not become effective until the current conversion cycle is complete. For example, if the old sample rate was 8 Hz, it will take up to 125 mS before the conversion cycle (and the CTRL_ACT register) are updated. This delay can be variable, depending on where we are in the conversion cycle when the REFRESH command is sent. bit 7-6 Sample_Rate<1:0> : shows the value that is currently active since the most recent REFRESH function was received for programmed sample rate in Normal mode (that is, if SLOW pin is not asserted) 00b = 1024 samples/s 01b = 256 samples/s 10b = 64 samples/s 11b = 8 samples/s bit 5 SLEEP : shows the value that is currently active since the most recent REFRESH function was received for the SLEEP bit. 0 = ACTIVE mode 1 = SLEEP mode, no data conversion bit 4 SING : shows the value that is currently active since the most recent REFRESH function was received for the single shot select bit, SING. 0 = Sequential scan mode 1 = Single-shot mode bit 3 ALERT_PIN : shows the value that is currently active since the most recent REFRESH function was received for the ALERT_PIN bit. 0 = Disable the ALERT pin function 1 = Enable the ALERT pin function bit 2 ALERT_CC : shows the value that is currently active since the most recent REFRESH function was received for the ALERT_CC bit. 0 = No ALERT on Conversion Cycle Complete 1 = ALERT function asserted for 5 μS on each completion of the conversion cycle bit 1 OVF ALERT : shows the value that is currently active since the most recent REFRESH function was received for the OVF ALERT bit. 0 = No ALERT if accumulator or accumulator counter overflow has occurred 1 = ALERT pin triggered if accumulator or accumulator counter has overflowed bit 0 OVF : shows the value that is currently active since the most recent REFRESH function was received for the OVF bit. 0 = No accumulator or accumulator counter overflow has occurred 1 = Accumulator or accumulator counter has overflowed |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |