| 전자부품 데이터시트 검색엔진 |
|
PD69104B1/F 데이터시트(PDF) 8 Page - Microsemi Corporation |
|
|
|||||||||||||||||||||||||||||
PD69104B1/F 데이터시트(HTML) 8 Page - Microsemi Corporation |
|
8 / 36 page ![]() 4-Port PoE Manager Microsemi Proprietary and Confidential. PD69104B1/F Datasheet Revision 2.0 5 event voltages to the ports, as required by the IEEE standard. 3.5 Current Limiter This circuit continuously monitors the current of the powered ports and limits it to a specific value, according to predefined limits set using the Current_Set pin. In case the current exceeds this specific level, the system starts measuring the elapsed time. If this period is longer than the preset threshold, the port is disconnected. 3.6 Main MOSFET Main power switching FET is used for controlling the PoE current that streams into the load. 3.7 IC and Port Parameters Monitoring A 10-bit analog-to-digital converter is used for converting analog signals into digital registers. IC main voltage monitoring—The chip main voltage is sampled every 1 mS. Each measurement is an average of four consecutive ADC measurements and stored in the relevant register. The main voltage measurement resolution is 5.835 mV/count ±5%. IC thermal monitoring—The PD69104B1/F contains a thermal sensor that is sampled to register every 1 mS so the PD69104B1/F die temperature can be monitored at all time. Port current/voltage monitoring—After the ports start to deliver the power the current/voltage is sampled every 1 mS on each port. Each measurement is an average of four consecutive ADC measurements and stored in the relevant register. Current measurement resolution is 122.07 µA /count ±5% and voltage measurement resolution is 5.835 mV/count ±5% (refer to the PD69104B1/F User Guide register map document for more details). 3.8 Power-on Reset (PoR) This element monitors the internal 3.3 V levels. If this voltage drops below specific thresholds, a reset DC signal is generated and the PD69104B1/F is reset. 3.9 Voltage Regulator The voltage regulator generates 3.3 V and 5 V for the internal circuitry. These voltages are derived DC DC from the V supply. main 3.10 Clock (CLK) This is an internal 8 MHz CLK oscillator. 3.11 I²C Address Selection The following table lists the I2C address selection for the PD69104B1/F device. Table 1 • I2C Address Selection CONST Bits ADDR3 Slave 1 Bit ADDR2 Slave 0 Bit ADDR1 ID1 Bit ADDR0 ID0 Bit I²C/UART Address 0 1 0 0 0 0 0 0100000b 0 1 0 0 0 0 1 0100001b 0 1 0 0 0 1 0 0100010b 0 1 0 0 0 1 1 0100011b 0 1 0 0 1 0 0 0100100b 0 1 0 0 1 0 1 0100101b 0 1 0 0 1 1 0 0100110b 0 1 0 0 1 1 1 0100111b 0 1 0 1 0 0 0 0101000b |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |