3 / 18 page ![]() Page 3/18 11July2018/Version 1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com LES series Insulation coordination Parameter Symbol Unit Value Comment RMS voltage for AC insulation test, 50 Hz, 1 min U d kV 4.3 Impulse withstand voltage 1.2/50 μs Û W kV 8 Insulation resistance R INS GΩ 18 measured at 500 V DC Partial discharge RMS test voltage (q m < 10 pC) U t kV 1.65 Clearance (pri. - sec.) d CI mm See dimensions drawing on page 19 Creepage distance (pri. - sec.) d Cp Case material - - V0 According to UL 94 Comparative tracking index CTI 600 Application example V 300 V CAT III, PD2 Reinforced insulation, non uniform field according to IEC 61800-5-1 Application example V 600 V CAT III, PD2 Basic insulation, non uniform field according to IEC 61800-5-1 Environmental and mechanical characteristics Parameter Symbol Unit Min Typ Max Comment Ambient operating temperature T A °C −40 105 Ambient storage temperature T S °C −55 125 Mass m g 10 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|