| 전자부품 데이터시트 검색엔진 |
|
L9346PD 데이터시트(PDF) 8 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9346PD 데이터시트(HTML) 8 Page - STMicroelectronics |
|
8 / 13 page ![]() CIRCUIT DESCRIPTION The L9346 is a quad low side driver for inductive loads like valves in automotive environment. The internal pull down current sources at the EN- ABLE and INPUT pins assure in case of open in- put conditions that the device is switched off. An output voltage slope limitation for du/dt is imple- mented to reduce the EMI. An integrated active flyback voltage limitation clamps the output volt- age during the flyback phase to 50 V. Each driver is protected against short circuit at VOUT < 32V and thermal overload. In short circuit condition the output will be disabled after a short delay time tDOL. The thermal disable for TJ > 180 °C of the output will be reseted if the junction temperature decreases about 20 °C below the dis- able threshold temperature. The overtemperatureinformation is stored until IN = L. For the real time error diagnosis the voltage and the current of the outputs are compared with in- ternal fixed values VOUV for OFF and IOUC for ON conditions to recognize open load (RL ≥ 20 KΩ, RL >38 Ω) in OFF and ON conditions. Also the output voltages VO1 - 4 are compared to each other output in OFF condition with a fixed offset of ∆VOUV to recognize load bypasses. To suppress the ∆VOUV diagnoses during the flyback phases of the compared output, the ∆VOUV diag- nostic includes a latch function. Reaching the flyback clamping voltage VOCL the diagnostic signal is reseted by a latch. To activate again this kind of diagnostic a low signal at the correspondent INPUT or the ENABLE pin must be applied (see also Fig.3). The outputs 1 and 4 are compared for ∆VOUV and also outputs 2 and 3 are compared. The diagnostic output level in connection with dif- ferent ENABLE and INPUT conditions allows to recognize different fail states, like overtemp, short to VSS, short to GND, bypass to GND and dis- connected load (see diagnostic table). The diagnostic output is protected against short circuit. Exceeding the over load current threshold IOOC, the output current will be limited internally during the diagnostic overload delay switch-off time tDOL. The device complies the ISO pulses imposed to the supply voltage of the valves without any fail- ures of the functionality. 5V t t 5V t 5A 3A IN V I O I OOL I OUC D V t DOL Figure 3. Diagnostic Overload Delay Time L9346 8/13 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |