2 / 5 page ![]() GO POUND GROUND ... ABOUT TEST LOADS IN CONSTANT CURRENT MODE Using Constant Current when setting up the test load allows you to set the Current Limit and Current Setpoint. Wavelength trimpots are 12-turn trimpots and are turned counter clockwise (CCW) for off and clockwise (CW) for on, the exception being the LDTC 2/2 E & O, where they are reversed. Consult the product documentation to verify the direction before proceeding. NOTE: The 12-turn trimpots continue to turn after the 12th turn has been reached. Any additional turns do not vary the resistance. 13 13 13 Figure 1. Example Test Loads for a Laser Diode in Constant Current Mode SET UP THE LASER DIODE TEST LOAD USING CONSTANT CURRENT MODE 1. Attach a test load between the Laser Diode Anode (LDA) and Laser Diode Cathode (LDC) of the laser diode driver (see Figure 1). 2. Set the driver in Constant Current mode. 3. Connect the multimeter, in voltage mode, between the Current Monitor (I MON) and common Ground (GND) pins. 4. Turn the Current Limit trimpot fully off, usually 12 full rotations counterclockwise (CCW). 5. Turn the Current Setpoint trimpot fully on, usually 12 full rotations clockwise (CW). 6. Attach a 5 V power supply. A higher voltage power supply can overheat the controller when using test loads. 7. Enable the unit. 8. Use the transfer function calculation in the datasheet to determine the I MON reading at the desired current limit. 9. Increase the Current Limit by turning the trimpot, usually CW, until the desired maximum I MON limit voltage is reached and then stop. The Current Limit is now set. 10.Use the transfer function to calculate the I MON voltage at the desired operating current. 11. Decrease the Current Setpoint by turning the trimpot, usually CCW, until the current starts to go down and the I MON voltage value is reached. 12.OPTIONAL: Wire a signal generator to the analog modulation input. The datasheet has the transfer function equations. 13.OPTIONAL: Replace the multimeter across the I MON and GND with an oscilloscope to monitor the output current variation with time. 14.Once the test load limits have been set and you are familiar with the system, return the Current Setpoint and Current Limit trimpots to their respective OFF positions (usually 12 turns CCW). NOTE: If testing a load in Constant Power mode, do NOT follow this step. © 2014 • Sales & Technical Support: (406) 587-4910 • email: Sales@teamWavelength.com • web: www.teamWavelength.com Application Note AN-LDTC04 Rev. A Page 2 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |