172 / 1524 page ![]() Section 3 DSP Operating Unit Rev. 3.00 Jan. 18, 2008 Page 110 of 1458 REJ09B0033-0300 3.4.4 Memory Data Formats Memory data formats that can be used in the DSP instructions are classified into byte and longword. An address error will occur if word data starting from an address other than 2n or longword data starting from an address other than 4n is accessed by MOVS.L, LDS.L, or STS.L instruction. In such cases, the data accessed cannot be guaranteed An address error will not occur if word data starting from an address other than 2n is accessed by the MOVX.W or MOVY.W instruction. When using the MOVX.W or MOVY.W instruction, an address must be specified on the boundary 2n. If an address is specified other than 2n, the data accessed cannot be guaranteed. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|