AT88SC0104C 데이터시트(PDF) 47 Page - ATMEL Corporation

부품명 AT88SC0104C
상세설명  CryptoMemory Specification For Standard Mode of Operation
PDF  58 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  ATMEL [ATMEL Corporation]
홈페이지  http://www.atmel.com
Logo ATMEL - ATMEL Corporation

AT88SC0104C 데이터시트(HTML) 47 Page - ATMEL Corporation

Back Button AT88SC0104C Datasheet HTML 43Page - ATMEL Corporation AT88SC0104C Datasheet HTML 44Page - ATMEL Corporation AT88SC0104C Datasheet HTML 45Page - ATMEL Corporation AT88SC0104C Datasheet HTML 46Page - ATMEL Corporation AT88SC0104C Datasheet HTML 47Page - ATMEL Corporation AT88SC0104C Datasheet HTML 48Page - ATMEL Corporation AT88SC0104C Datasheet HTML 49Page - ATMEL Corporation AT88SC0104C Datasheet HTML 50Page - ATMEL Corporation AT88SC0104C Datasheet HTML 51Page - ATMEL Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 47 / 58 page
background image
44
5210B–SMIC–11/08
AT88SC0104/0204/0404/0808/1616/3216/6416/12816/25616C
8.5.4
System READ: $B6
8.5.4.1
Functional
Figure 8-4.
System READ Command Functional Description
The System Read command allows reading of the system data from the device. Depending on
the value of the P1 parameter, the host may read the data in the configuration memory, or the
fuses.
8.5.4.2
Read Config Zone
To read 256 bytes, the host should set N = $00. This is true for any outgoing command, and is
defined by ISO 7816-3. If the address provided at P2 is an unauthorized address, the device will
return the "Command Unauthorized" code ($69 $00) after it has received the header. Since
access rights vary throughout the configuration memory, the host may provide an authorized
starting address, but a number of bytes N that causes the device to reach unauthorized address.
In this case, the device will transmit the authorized bytes, but unauthorized bytes will be
replaced by the "fuse byte" (see below). At the end of this command the "Command Unauthor-
ized" code ($69 $00) will be returned instead of $90 $00 to indicate that some of the bytes
returned were not valid.
Device
Command
Parameter P1
Parameter P2
Number of Bytes N
Host
N data bytes
Data
...
Data
Table 8-11.
System READ Command Detail
Command
CLA
INS
P1
P2
P3
Read Config Zone
$00
$B6
$00
addr
N
Read Fuse Byte
$00
$B6
$01
$00
$01
Table 8-12.
System READ
System READ
Data Returned
CLA
INS :
Command
P1
P2
P3
Data(1)
...
Data(N)
**
$B6
p
7--- ---p0
p
7--- ---p0
n
7 --- n0
d
7--- ---d0
...
d
7--- ---d0



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com