VT10 데이터시트(PDF) 2 Page - Extech Instruments Corporation. |
|
|
|||||||||||||||||||||||||||||
VT10 데이터시트(HTML) 2 Page - Extech Instruments Corporation. |
|
2 / 6 page ![]() VT10 V2.0 08/06 2 Introduction Congratulations on your purchase of the Extech VT10 Multifunction Voltage Tester. The VT10 measures AC Voltage to 600V and DC Voltage to 400V with LED indicators, and LEDs for positive and negative polarity. Additional features include audible continuity beeper, low impedance mode for eliminating phantom voltages, and a built-in flashlight to illuminate test connections during measurements. This meter is shipped fully tested and with proper use will provide years of reliable service. Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation Safety Precautions 1. Improper use of this meter can cause damage, shock, injury or death. Read and understand this manual before use. 2. Ensure that any covers or battery doors are properly closed and secured before use. 3. Inspect the condition of the test leads and the meter itself for any damage before use. 4. Do not exceed the rated input limits. 5. Use great care when taking measurements greater than 25VAC rms or 35VDC. These voltages are considered a shock hazard. 6. Discharge capacitors and remove power from the DUT before Continuity tests. 7. Remove the batteries from the meter if the meter is to be stored for long periods. 8. Voltage measurement results on electrical outlets can be misleading because of the difficulty in making a proper connection to the electrical contacts. 9. NEVER apply voltage to the meter that exceeds the specified maximum: Input Protection Limits Function Maximum Input VAC, VDC, Continuity 600VAC: 30 second max 400VDC: 30 second max 10. USE EXTREME CAUTION when working with high voltages. 11. ALWAYS discharge filter capacitors in power supplies and disconnect the power when making continuity tests. 12. ALWAYS disconnect the test leads before opening the cover to replace the battery. 13. NEVER operate the meter unless the battery cover is in place and fastened securely. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |