13 / 23 page ![]() Advanced Information WM8722 WOLFSON MICROELECTRONICS LTD AI Rev 1.5 May 2000 13 LATCH STATE Address 1 1000001 0 1000000 To control the WM8722 on the bus, the master must initiate a data transfer by establishing a start condition, defined by a high-to-low transition on MD whilst MC remains high. This indicates that an address and data transfer will follow. All peripherals respond to the start condition and shift the next eight bits (7-bit address + R/W bit). The transfer is MSB first. The peripheral that recognises the transmitted address responds by pulling the data line low during the ninth clock pulse (acknowledge bit). All other devices withdraw from the bus and maintain an idle condition once the appropriate peripheral has been recognised. The idle condition is where the device monitors the MD and MC lines waiting for a start condition and the correct transmitted address. The R/W bit determines the direction of data transfer. The WM8722 is a write only device and only responds to the R/W bit indicating a write. The WM8722 acts as a standard slave device on the bus. The data on the MD is clocked in by MC. The first 6 bits (which must be 100000) are clocked into the WM8722 followed by a programmable address bit to select one of the two available addresses. The eighth bit of the address byte is the R/W bit. The WM8722 checks this bit and responds if it is a write. If the correct address is sent by the master, the WM8722 acknowledges the bus master (ACK) and pulls the bus low. The next byte is the register address. Each subsequent byte of data is separated by an acknowledge bit. A stop condition is defined when there is a low-to-high transition on MD when MC is high. If a stop or start condition is detected out of sequence at any point in the data transfer, the device jumps to the idle condition. SERIAL CONTROL OPERATION Control of the various modes of operation is software control over the 2 or 3-wire serial interface. The following functions may be controlled via the serial control interface: FUNCTION OPTIONS SOFTWARE CONTROL DEFAULT VALUE Input audio data format Normal format I 2S format Normal format (0) Input Word Length 16 20 24 16 bit (0) De-emphasis selection On Off Off (0) Operation enable (OPE) (power down) Enable disable Enabled (0) Analogue output mode L, R, mono, Mute Stereo (1001) Mute On (Muted) Off (Un-muted) Off (0) Input LRCIN polarity Lch/Rch = Hi/Lo Lch/Rch = Lo/Hi Lch/Rch = Hi/Lo (0) Master Volume Control Lch, Rch individually Lch, Rch both 0dB (1111001) Lch, Rch individually (0) |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |