5 / 20 page ![]() Data Sheet TLE 6232 GP V2.3 Page 2009-11-18 5 Electrical Characteristics Parameter and Conditions Symbol Values Unit VS = 4.5 to 5.5 V ; Tj = - 40 °C to + 150 °C ; Reset = H (unless otherwise specified) min typ max 1. Power Supply, Reset Supply Voltage 2 VS 4.5 -- 5.5 V Supply Current IS -- -- 10 mA Supply Current in Standby Mode (RESET = L) IS(stdy) -- -- 10 µA Minimum Reset Duration tReset,min 1 -- -- µs 2. Power Outputs ON Resistance VS = 5 V; ID = 1 A TJ = 25°C Channel 1-4 TJ = 150°C RDS(ON) -- -- 0.25 -- 0.28 0.5 Ω ON Resistance VS = 5 V; ID = 500 mA TJ = 25°C Channel 5,6 TJ = 150°C RDS(ON) -- -- 0.45 -- 0.55 1 Ω Output Clamping Voltage Output OFF VDS(AZ) 45 53 60 V Current Limit Channel 1-4 Current Limit Channel 5,6 ID(lim) 1-4 ID(lim) 5,6 3 1.5 4 2 6 3 A Output Leakage Current VReset = L ID(lkg) -- -- 10 µA Turn-On Time Ch 1-4 ID = 2 A, resistive load Ch 5,6 ID = 1 A, resistive load tON -- 5 10 µs Turn-Off Time Ch 1-4 ID = 2 A, resistive load Ch 5,6 ID = 1 A, resistive load tOFF -- 5 10 µs Switch-On Slew Rate (resistive load) son 1 4 20 V/µs Switch-Off Slew Rate (resistive load) son 1 4 20 V/µs 3. Digital Inputs Input Low Voltage VINL - 0.3 -- 1.0 V Input High Voltage VINH 2.0 -- -- V Input Voltage Hysteresis VINHys 100 200 400 mV Input Pull Down/Up Current (IN1 ... IN6) IIN(1..6) 10 20 50 µA Input Pull Up Current (Reset) IIN(Res) 10 20 50 µA Input Pull Down Current (PRG) IIN(PRG) 10 20 50 µA Input Pull Up Current ( CS , SI, SCLK) IIN(SI,SCLK) 10 20 50 µA 4. Digital Outputs (SO, FAULT ) SO High State Output Voltage ISOH = -2 mA VSOH VS - 1 -- -- V SO Low State Output Voltage ISOL = 2 mA VSOL -- -- 0.4 V Output Tri-state Leakage Current CS = H, 0 ≤ V SO ≤ V S ISOlkg -10 0 10 µA FAULT Output Low Voltage IFAULT = 2 mA VFAULTL -- -- 0.4 V 2 For V S < 4.5V the power stages are switched according the input signals and data bits or are definitely switched off. This under-voltage reset gets active at VS = 3V (typ. value) and is specified by design. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |