11 / 22 page ![]() iC-MP 8-BIT HALL ANGLE ENCODER WITH RATIOMETRIC OUTPUT Rev B1, Page 11/22 OPERATING MODES Figure 10: Operation Modes Figure 10 shows the different modes of iC-MP. There are two major modes of operation: • Normal Mode: Readout position data and error bit. Normal mode is subdivided into two minor modes of operation: – Fast Scanning Mode: iC-MP is always activated. – Slow Scanning Mode (Power Save Mode): iC-MP goes into Slow Mode Sleep following the first transmission of sensor data via the serial interface. • Programming Mode: iC-MP can be configured in programming mode. See the chapter on ’PROGRAMMING MODE’ for further details. There are three minor modes: – Read ROM: iC-MP’s Zener zap ROM structure is read. – Write RAM: iC-MP’s internal registers can be temporarily programmed for test purposes. – Write ROM: iC-MP’s zapping structure is programmed. A Power-On Reset is required after a Read ROM and Write ROM instruction. Each state is quit by a Power- On Reset. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|