| 전자부품 데이터시트 검색엔진 |
|
APTH003A0X 데이터시트(PDF) 2 Page - Lineage Power Corporation |
|
|
|||||||||||||||||||||||||||||
APTH003A0X 데이터시트(HTML) 2 Page - Lineage Power Corporation |
|
2 / 24 page ![]() Data Sheet December 10, 2010 Pico TLynxTM 3A: Non-isolated DC-DC Power Modules 2.4 – 5.5Vdc input; 0.6Vdc to 3.63Vdc output; 3A output current LINEAGE POWER 2 Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage All VIN -0.3 6 Vdc Continuous Sequencing Voltage APTH VSEQ -0.3 ViN, Max Vdc Operating Ambient Temperature All TA -40 85 °C (see Thermal Considerations section) Storage Temperature All Tstg -55 125 °C Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit Operating Input Voltage All VIN 2.4 ⎯ 5.5 Vdc Maximum Input Current All IIN,max 3.5 Adc (VIN=2.4V to 5.5V, IO=IO, max ) Input No Load Current VO,set = 0.6 Vdc IIN,No load 26 mA (VIN = 5.0Vdc, IO = 0, module enabled) VO,set = 3.3Vdc IIN,No load 75 mA Input Stand-by Current All IIN,stand-by 2.1 mA (VIN = 5.0Vdc, module disabled) Inrush Transient All I 2t 1 A 2s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1μH source impedance; VIN =0 to 5.5V, IO= IOmax ; See Test Configurations) All 25 mAp-p Input Ripple Rejection (120Hz) All 40 dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a maximum rating of 5A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |