30 / 77 page ![]() Theory of operation STPMC1 30/77 Doc ID 15728 Rev 6 The value IMAX corresponds to the maximum current value hold by each RMS current register (internal value FFFF). It is a function of the sensor type, sensitivity and of the current channel gain. Let us suppose that IMAX = 180 A The tamper condition is evaluated only if This means that the sum of the RMS value of currents is not negligible with respect to IMAX (the threshold corresponds to about 0.4% of IMAX). In this case this is true since: IR + IS +IT +IN = 14.4 A > 0,703125 A = IMAX / 256 The criterion for tamper detection is This can also be expressed as which means the sIRMS value must not exceed 3.13% of (IR + IS +IT +IN). In this example: sIRMS = 0,149967 < 0.45 = (IR + IS +IT +IN) / 32 Then BCS = 0. Figure 11. Currents of the three phase system in example ∑ > + + + = 256 I I I I I I MAX N T S R X () 8 I i X RMS X ∑ ∑ > () 32 I 4 i 4 i sIRMS X RMS X RMS X ∑ ∑ ∑ > = ⎟ ⎠ ⎞ ⎜ ⎝ ⎛ = |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|