15 / 35 page ![]() ib technology 15 Note that as mentioned for the WRITE command, Mifare Ultralight cards DO NOT USE Security Keys or Authentication and the memory is organised differently as groups of 4 bytes (Pages). However, unlike the Write command, 16 bytes (4 pages) can be read in a single operation The same Read command as above is used except the “Block” address is treated as a “Page Address” and the KeyType/Key number parameter is a dummy 0x00 byte. For page numbers greater than 12, the card data wraps around to page 0 etc. B7 B0 Command: 0 1 0 1 0 0 1 0 (Ascii “R”, 0x52) Argument1: x x x x N N N N (N = UL Card Page Address 0 – 15) Argument2: 0 0 0 0 0 0 0 0 (Dummy byte, 0x00) Acknowledge: 1 F F F F F F X (F = Status flags) Data only follows if Read was successful Reply1: D D D D D D D D (D = LS Byte of data Read from UL card) Reply2: D D D D D D D D Reply3: D D D D D D D D Reply4: D D D D D D D D 16 Bytes of data Reply13: D D D D D D D D Reply14: D D D D D D D D Reply15: D D D D D D D D Reply16: D D D D D D D D (D = MS Byte of data Read from UL card) Inc Value (only operates on Value Data Structure) Command to increment integer within a Value Data Structure. The command loads the value from the specified block address, adds the integer parameter and stores the result at the same or another block address. Note that the source block must have been formatted as a Value Block beforehand according to the data structure below, using the WRITE command. The INC Value command only operates on a "Value Block Structure" and will fail if the block configuration or the specified key type is incorrect. Value Block Structure Example format for value = 100 decimal (0x64), at block address 0. (Value data stored LS byte first, ADR = block address, ADR = inverted block address) 0x64 00 00 00 9B FF FF FF 64 00 00 00 00 FF 00 FF Byte: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 The first argument is the source block address to load data from, the second argument specifies which key code and type to use for sector authentication (0-31 and if it is KeyA or KeyB type). Value Inverted Value Value ADR ADR ADR ADR |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |