| 전자부품 데이터시트 검색엔진 |
|
MJ802 데이터시트(PDF) 2 Page - Motorola, Inc |
|
|
|||||||||||||||||||||||||||||
MJ802 데이터시트(HTML) 2 Page - Motorola, Inc |
|
2 / 4 page ![]() MJ802 2 Motorola Bipolar Power Transistor Device Data ELECTRICAL CHARACTERISTICS (TC = 25_C unless otherwise noted) Characteristic Symbol Min Max Unit OFF CHARACTERISTICS Collector–Emitter Breakdown Voltage(1) (IC = 200 mAdc, RBE = 100 Ohms) BVCER 100 — Vdc Collector–Emitter Sustaining Voltage(1) (IC = 200 mAdc) VCEO(sus) 90 — Vdc Collector–Base Cutoff Current (VCB = 100 Vdc, IE = 0) (VCB = 100 Vdc, IE = 0, TC = 150_C) ICBO — — 1.0 5.0 mAdc Emitter–Base Cutoff Current (VBE = 4.0 Vdc, IC = 0) IEBO — 1.0 mAdc ON CHARACTERISTICS(1) DC Current Gain(1) (IC = 7.5 Adc, VCE = 2.0 Vdc) hFE 25 100 — Base–Emitter “On” Voltage (IC = 7.5 Adc, VCE = 2.0 Vdc) VBE(on) — 1.3 Vdc Collector–Emitter Saturation Voltage (IC = 7.5 Adc, IB = 0.75 Adc) VCE(sat) — 0.8 Vdc Base–Emitter Saturation Voltage (IC = 7.5 Adc, IB = 0.75 Adc) VBE(sat) — 1.3 Vdc DYNAMIC CHARACTERISTICS Current Gain — Bandwidth Product (IC = 1.0 Adc, VCE = 10 Vdc, f = 1.0 MHz) fT 2.0 — MHz (1)Pulse Test: Pulse Width v 300 µs, Duty Cycle v 2.0%. IC, COLLECTOR CURRENT (AMP) TJ = 175° C 3.0 IC, COLLECTOR CURRENT (AMP) 1.0 2.0 0.7 1.0 0.5 0.1 Figure 2. DC Current Gain Figure 3. ‘‘On” Voltages VBE(sat) @ IC/IB = 10 VCE = 2.0 V 25 °C – 55 °C TJ = 25°C 0.03 0.1 0.2 0.3 0.5 10 20 30 0.3 0.2 0.05 2.0 3.0 5.0 DATA SHOWN IS OBTAINED FROM PULSE TESTS AND ADJUSTED TO NULLIFY EFFECT OF ICBO. 2.0 1.8 1.4 1.6 1.2 0 1.0 0.8 0.6 0.4 0.2 1.0 0.03 0.1 0.2 0.3 0.5 10 20 30 0.05 2.0 3.0 5.0 VBE @ VCE = 2.0 V VCE(sat) @ IC/IB = 10 50 1.0 VCE, COLLECTOR–EMITTER VOLTAGE (VOLTS) 5.0 20 10 1.0 0.2 10 Figure 4. Active Region Safe Operating Area 100 5.0 2.0 0.5 0.1 20 2.0 3.0 100 50 30 SECONDARY BREAKDOWN LIMITED BONDING WIRE LIMITED THERMAL LIMITATIONS TC = 25°C PULSE DUTY CYCLE ≤ 10% TJ = 200° C 100 µs 1.0 ms 5.0 ms dc The Safe Operating Area Curves indicate IC – VCE limits below which the device will not enter secondary breakdown. Collector load lines for specific circuits must fall within the applicable Safe Area to avoid causing a catastrophic failure. To insure operation below the maximum TJ, power tempera- ture derating must be observed for both steady state and pulse power conditions. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |