부품명 CT2555
상세설명  CT2553 / 2554 / 2555 / 2556 Advanced Integrated MUX (AIM) Hybrid FOR MIL-STD-1553
PDF  36 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  AEROFLEX [Aeroflex Circuit Technology]
홈페이지  http://www.aeroflex.com
Logo AEROFLEX - Aeroflex Circuit Technology

CT2555 데이터시트(HTML) 22 Page - Aeroflex Circuit Technology

Back Button CT2555 Datasheet HTML 18Page - Aeroflex Circuit Technology CT2555 Datasheet HTML 19Page - Aeroflex Circuit Technology CT2555 Datasheet HTML 20Page - Aeroflex Circuit Technology CT2555 Datasheet HTML 21Page - Aeroflex Circuit Technology CT2555 Datasheet HTML 22Page - Aeroflex Circuit Technology CT2555 Datasheet HTML 23Page - Aeroflex Circuit Technology CT2555 Datasheet HTML 24Page - Aeroflex Circuit Technology CT2555 Datasheet HTML 25Page - Aeroflex Circuit Technology CT2555 Datasheet HTML 26Page - Aeroflex Circuit Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 36 page
background image
Aeroflex Circuit Technology
22
SCDCT2553 REV B 8/6/99 Plainview NY (516) 694-6700
OVERRIDE TRANSMITTER SHUTDOWN (00101)
MESSAGE SEQUENCE - OVERRIDE SHUTDOWN - STATUS
This command is only used with dual redundant bus systems. The CT2553 responds with status. At the end of the status transmission, the
CT2553 re-enables the transmitter of the redundant bus. If the command was broadcast, the broadcast received bit is set and status
transmission is suppressed.
ERROR CONDITIONS
1. Invalid Command. No response, command ignored.
2. Command Followed by Data Word. No status response. Bits set: message error (SW), High Word Count (BIT Word).
3. T/R bit Set to Zero. No status response. Bits set: message error (SW), T/R Error (BIT Word).
4. Zero T/R bit and Broadcast Address. No status response. Bits set: message error, broadcast received (SW), Illegal Mode Code, T/R
Error (BIT Word).
INHIBIT TERMINAL FLAG BIT (00110)
MESSAGE SEQUENCE - INHIBIT TERMINAL FLAG * STATUS
The CT2553 responds with status and inhibits further internal or external setting of the terminal flag bit in the status register. Once the
terminal flag has been inhibited, it can only be reactivated by an Override Inhibit Terminal Flag or Reset RT command. If the command was
broadcast, the broadcast received bit is set and status transmission is suppressed.
ERROR CONDITIONS
1. Invalid Command. No response, command ignored.
2. Command Followed by Data Word. No status response. Bits set: message error (SW), High Word Count (BIT Word).
3. T/R bit Set to Zero. No status response. Bits set: message error (SW), T/R Error (BIT Word).
4. Zero T/R bit and Broadcast Address. No status response. Bits set: message error, broadcast received (SW), T/R Error (BIT Word).
OVERRIDE INHIBIT TERMINAL FLAG BIT (00111)
MESSAGE SEQUENCE - OVERRIDE INHIBIT TERMINAL FLAG * STATUS
The RTU responds with status and reactivates the terminal flag bit in the status register. If the command was broadcast, the broadcast
received bit is set and status transmission is suppressed.
ERROR CONDITIONS
1. Invalid Command. No response, command ignored.
2. Command Followed by Data Word. No status response. Bits set: message error (SW), High Word Count (BIT Word).
3. T/R bit Set to Zero. No status response. Bits set: message error (SW), T/R Error (BIT Word).
4. Zero T/R bit and Broadcast Address. No status response. Bits set: message error, broadcast received (SW), T/R Error (BIT Word).
RESET REMOTE TERMINAL (01000)
MESSAGE SEQUENCE - RESET REMOTE TERMINAL * STATUS
The CT2553 responds with status and internally resets. Transmitter shutdown, mode commands, and inhibit terminal flag commands will be
reset. If the command was broadcast, the broadcast received bit is set and the status word is suppressed.
ERROR CONDITIONS
1. Invalid Command. No response, command ignored.
2. Command Followed by Data Word. No status response. Bits set: message error (SW), High Word Count (BIT Word).
3. T/R bit Set to Zero. No status response. Bits set: message error (SW), T/R Error (BIT Word).
4. Zero T/R bit and Broadcast Address. No status response. Bits set: message error, broadcast received (SW), T/R Error (BIT Word).
RESERVED MODE CODES (01001-01111)
MESSAGE SEQUENCE = RESERVED MODE CODES * STATUS
The CT2553 responds with status. If the command is illegalized through an optional PROM, the message error bit is set and only the status
word is transmitted.
ERROR CONDITIONS
1. Invalid Command. No response, command ignored.
2. Command Followed by Data Word. No status response. Bits set: message error (SW), High Word Count (BIT Word).
3. T/R bit Set to Zero. No status response. Bits set: message error (SW), Illegal Mode Code (BIT Word).
4. Zero T/R bit and Broadcast Address. No status response. Bits set: message error, broadcast received (SW), Illegal Mode Code (BIT
Word).
Table 6 – Mode Codes (continued)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com