| 전자부품 데이터시트 검색엔진 |
|
E5CN-RML-500 데이터시트(PDF) 65 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CN-RML-500 데이터시트(HTML) 65 Page - Omron Electronics LLC |
|
65 / 72 page ![]() E5 @N/E5@N-H 65 M M M M M M M M M M M M M M M M M init off M M M M M M M spru m rest a sb1n n-o sb2n n-o sb3n n-o hbh 0.1 hbu on hbl off M a3lt ret o-dp M M M M M M M M M M M M M M off off off M M M st-b 15.0 c alfa 0.65 at-g at-h lcma 20.0 inf 0.0 pvad off a1lt off a2lt off prlt 3 sero off colr red rlrv off pv-b 5.0 c M cjc on M M M M M M M M M M M M istp ins1 mvse off amad on rt off hsu on hsl off hsh 0.1 lba 0 lbab 3.0 c out1 o out2 none 8.0 c lbal p-db 0.0 M M M M M M M M M M M M M rspu off rsph 1300.0 rspl -200.0 sptr off rseo off pidh 0.50 manl off pmvd off pvrp 17 csca off pidi pv pfd1 1 pfd2 0 pfd3 0 pfd4 0 pfd5 0 spdp 4 odsl o pvdp on pvst off svst off ra1m 0 ra2m 0 ra1 0 ra2 0 rac 0 cmov 0 c c c c M M M M M 0 a1on 0 a2on 0 a3on 0 a1of a2of 0 a3of 0 M M M M sub1 alm1 sub2 alm2 csel on t-u m sub3 alm3 M M ocl off ocu on och 0.1 M pf a-m 0.8 1.0 M alsp sp-m M M M d.ref 0.25 0 RT Press the O Key for at least 1 s. Advanced Function Setting Level Parameter Initialization SP Ramp Time Unit Standby Sequence Reset Auxiliary Output 1 Open in Alarm Auxiliary Output 2 Open in Alarm Auxiliary Output 3 Open in Alarm HB ON/OFF Heater Burnout Latch Heater Burnout Hysteresis ST Stable Range AT Calculated Gain α AT Hysteresis Limit Cycle MV Amplitude Input Digital Filter Additional PV Display MV Display Automatic Display Return Time Alarm 1 Latch Alarm 2 Latch Alarm 3 Latch Move to Protect Level Time Input Error Output Cold Junction Compensation Method MB Command Logic Switching PV Change Color PV Stable Band Alarm 1 ON Delay Alarm 2 ON Delay Alarm 3 ON Delay Alarm 1 OFF Delay Alarm 2 OFF Delay Alarm 3 OFF Delay Input Shift Type MV at Stop and Error Addition Auto/Manual Select Addition HS Alarm Use HS Alarm Latch HS Alarm Hysteresis LBA Detection Time LBA Level LBA Band Control Output 1 Assignment Control Output 2 Assignment Auxiliary Output 1 Assignment Auxiliary Output 2 Assignment Auxiliary Output 3 Assignment (E5AN/E5EN-H only) Character Select Soak Time Unit Alarm SP Selection Manual MV Limit Enable PV Rate of Change Calculation Period Automatic Cooling Coefficient Adjustment Heater Overcurrent Use Heater Overcurrent Latch Heater Overcurrent Hysteresis Move to Calibration Level PF Setting Monitor/Setting Item 1 Monitor/Setting Item 2 Monitor/Setting Item 3 Monitor/Setting Item 4 Monitor/Setting Item 5 "PV/SP" Display Screen Selection MV Display Selection PV Decimal Point Display PV Status Display Function SV Status Display Function Display Refresh Period Control Output 1 ON/OFF Count Monitor Control Output 2 ON/OFF Count Monitor Control Output 1 ON/OFF Count Alarm Set Value Control Output 2 ON/OFF Count Alarm Set Value ON/OFF Counter Reset Power ON Manual Control Level Operation Level Initial Setting Level Adjustment Level Protect Level Monitor/Setting Item Level PID Setting Level Bank Setting Level Remote SP Enable Remote SP Upper Limit Remote SP Lower Limit SP Tracking Remote SP Input Error Output PID Set Automatic Selection Data PID Set Automatic Selection Hysteresis PV Dead Band Direct Setting of Position Proportional MV Advanced Function Setting Level Communica- tions Setting Level |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |