| 전자부품 데이터시트 검색엔진 |
|
AS5055 데이터시트(PDF) 10 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS5055 데이터시트(HTML) 10 Page - ams AG |
|
10 / 26 page ![]() www.ams.com/AS5055 Revision 1.16 10 - 26 AS5055 Datasheet - Detailed Descr i p ti on 7.2.3 Write Data Package (Value Written to AS5055) The write frame is compatible to the read frame and contains two additional bits, the don’t care and parity flag. If the previous command was a write command a second package has to be transmitted. 7.2.4 Register Block Table 8. Write Package Bit MSB 14 13 12 11 10 9 8 7 6 5 4 3 2 1 LSB Data <13:0> Don’t care PAR Bit Description Data 14-bit data to write to former selected address PAR Parity bit (EVEN) Table 9. Register Block Register Bit Mode Reset Value Bit Description Power ON Reset (POR) Register - [0x3F22] POR_OFF 8 R/W 0x00 <7:0> The POR cell is deactivated when the value 0x5A is written to this register (30µA reduction of current consumption) Software Reset Register - [0x3C00] software_reset 14 W 0x000 <13:0> Refer to SOFTWARE RESET Command on page 13 Master Reset Register - [0x33A5] master_reset 14 W 0x000 <13:0> Inject a power on reset cycle Clear Error Flag Register - [0x3380] clr_error_flag 14 R 0x000 <13:0> Refer to CLEAR ERROR FLAG Command on page 12 No Operation Register - [0x0000] NOP 14 w 0x000 <13:0> Refer to NOP Command on page 14 Automatic Gain Control (AGC) Register - [0x03FF8] AGC 6 R/W 0x20 <5:0> Automatic gain control: low values = strong magnetic field high values = weak magnetic field Angular Data - [0x3FFF] Angle Value 12 R 0x000 <11:0> Measured angular value, 12-bit Alarm LO 1 R 0 <12> Alarm bit indicating a too high magnetic field, active HIGH. Refer to Error Monitoring on page 14 Alarm HI 1 R 0 <13> Alarm bit indicating a too low magnetic field, active HIGH. Refer to Error Monitoring on page 14 System Configuration Register 1 - [0x3F20] resolution 2 R ‘00’ <13:12> ‘00’ indicates 12-bit resolution chip ID 3 R ‘001’ <11:9> Silicon version 001 Error Status Register - [0x335A] error_status 14 R 0x000 <13:0> Refer to Error Status Command on page 15 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |