| 전자부품 데이터시트 검색엔진 |
|
SC402S 데이터시트(PDF) 21 Page - 3M Electronics |
|
|
|||||||||||||||||||||||||||||
SC402S 데이터시트(HTML) 21 Page - 3M Electronics |
|
21 / 29 page ![]() 3M™ MicroTouch™ Controller RX142 Reference Guide 21 3M Touch Systems, Inc. Proprietary Information Figure 2 Calibration Target Locations Enter Sleep Syntax: <SOH>ES<CR> Response: <SOH>0<CR> Positive response. Description: This command is a power management feature that lets you put the controller into a low power mode (4-5 mA) when not in use. Send this command to put the controller in a low power state. The controller returns to a normal power level on touch. If you need to send a command to the controller when it is in a low power state, first raise CTS. Format Tablet Syntax: <SOH>FT<CR> Response: <SOH>0<CR> Positive response. The controller will respond with ACK for compatibility with older controllers. This format is the only format supported by this controller. With the controller in Format Tablet mode, touching the sensor causes the controller to return a response in the following format: SXxYy S = Status byte, first byte of data. Refer to Table 4. Xx = X (horizontal) coordinate data; second and third bytes of data. Yy = Y (vertical) coordinate data; fourth and fifth bytes of data. Description: Outputs the X/Y touch coordinate data in a 5-byte packet. The packet includes 1 status byte and 4 bytes of binary X/Y coordinate data. The protocol also establishes the X and Y coordinate output as 14 binary bits providing a range of 0 to 16,383. Upper Right Calibration Target X = 1023 – (1024 x 1/8) = 1023 – 128 = 895 Y = 0 + (768 x 1/8) = 0 + 96 = 96 Lower Left Calibration Target X = 0 + (1024 x 1/8) = 0 + 128 = 128 Y = 767 - (768 x 1/8) = 767 - 96 = 671 (0, 0) [0, 1024]* (0, 767) [0, 0]* (1023, 0) [1024, 1024]* (128, 671) (895, 96) [1024, 0]* * The coordinates are in video terms, with the origin (0, 0) in the upper left corner of the sensor. Examples from the controller’s perspective however, place the origin at the lower left corner of the sensor (numbers in brackets). The controller outputs 0 to 1024 for both axes, regardless of display resolution. (128, 96) Upper Left Calibration Target X = 1024 x 1/8 = 128 Y = 768 x 1/8) = 96 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |