13 / 15 page ![]() AN4451 Conclusion DocID025985 Rev 1 13/15 5 Conclusion UV sensors provide an extremely small current depending of the level of UV radiation. To convert this current to an adequate voltage, a transimpedance amplifier is used. Then, an ADC can convert the signal into the digital domain. For this kind of application, it is important to choose a CMOS rail-to-rail amplifier with a low Vio to avoid inducing big errors on the output. The OA1MPA is a good option for such a UV sensor application. However, stability must be also taken into account and the right components must be chosen, particularly the feedback capacitor Cf which helps to stabilize the system, limit bandwidth, and reduce noise. Benefit from a wide portfolio of analog switches, voltage references, temperature sensors, pressure sensors, or microcontrollers to develop your application, by making STMicroelectronics your one-stop shop as illustrated in Figure 10. Figure 10: UV sensor evaluation board |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|