18 / 26 page ![]() 3-phase systems AN3157 18/26 Doc ID 17105 Rev 1 A.1 Power in 3-phase AC circuits Let's assume that the angle between the phase voltage and the phase current is θ, which is equal to the angle of the load impedance. Considering the load configurations given in Figure 13, the phase power and the total power can be easily estimated. In the case of Figure 13 (a), the total active power is equal to three times the power of one phase: Equation 1 Equation 2 Since the line current in the balanced delta-connected loads is: Equation 3 If Equation 3 is substituted into Equation 2, the total active load becomes: Equation 4 In Figure 13 (b), however, the impedances contain the line currents Iline (equal to the phase current, Iphase) and the phase voltages: Figure 13. Per-phase powers in (a) delta-connected load and (b) wye-connected load. θ = = = = cos I V P P P P phase line 3 2 1 θ = = cos I V 3 P 3 P phase line Total phase line I 3 I = θ = cos I V 3 P line line Total |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|