Back Button AN2747 Datasheet HTML 3Page - STMicroelectronics AN2747 Datasheet HTML 4Page - STMicroelectronics AN2747 Datasheet HTML 5Page - STMicroelectronics AN2747 Datasheet HTML 6Page - STMicroelectronics AN2747 Datasheet HTML 7Page - STMicroelectronics AN2747 Datasheet HTML 8Page - STMicroelectronics AN2747 Datasheet HTML 9Page - STMicroelectronics AN2747 Datasheet HTML 10Page - STMicroelectronics AN2747 Datasheet HTML 11Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 44 page
background image
AN2747
Lamp description
7/44
Figure 6.
Instantaneous lamp power with sinusoidal and square waveforms
For ideal square waveforms, the instant power delivered to the lamp is constant and not
modulated by any frequency. This driving plus the low frequency driving allows obtaining a
system that is immune to the problem of acoustic resonance.
For this reason HID lamp applications using square wave current techniques are the best
solution.
1.1
Lamp phases
1.1.1
Ignition phase
The ignition voltage for HID lamps is higher with respect to the mains voltage. The peak
voltage value to initiate the discharge is very high. Typically this is about 3 kV ÷ 5 kV.
The voltage level at which an HID lamp ignites is called "ignition voltage". This voltage level
is referred to the lamp when it is cold but this value increases with lamp temperature.
To ensure immediate HID lamp restart, called “hot restrike”, very high re-ignition peaks are
necessary (about 20 kV).
Standard luminaries are not designed for hot restrike voltages. For this reason in order to
obtain hot lamp re-ignition, several minutes must elapse for the lamp to cool. The restart
time depends on lamp temperature.
1.1.2
Warm-up
When the discharge has been initiated by the starting gas and the lamp still does not burn
properly, a warm-up time is required.
During the warm-up time the gas temperature increases, increasing the light output. The
lamp voltage starts approximately from a quarter of Vlamp and increases up to Vlamp.
Instantaneous Power
Voltage
Current
Instantaneous Power
Voltage
Current



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com