| 전자부품 데이터시트 검색엔진 |
|
3850 데이터시트(PDF) 59 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
3850 데이터시트(HTML) 59 Page - Renesas Technology Corp |
|
59 / 103 page ![]() Rev.3.01 2003.06.20 page 57 of 98 3850 Group (Spec.H/A) qErase All Blocks Command (2016/2016) By writing the command code “2016” in the first bus cycle and the confirmation command code “2016” in the second bus cycle that follows, the operation of erase all blocks (erase and erase verify) starts. Whether the erase all blocks command is terminated can be con- ____ firmed by reading the status register or the RY/BY Status Flag of flash memory control register. When the erase all blocks operation starts, the read status register mode is entered automatically and the contents of the status register can be read out at the data bus (D0 to D7). The status register bit 7 (SR7) is set to “0” at the same time the erase operation starts and is returned to “1” upon comple- tion of the erase operation. In this case, the read status register mode remains active until another command is written. ____ The RY/BY Status Flag is “0” during erase operation and “1” when the erase operation is completed as is the status register bit 7 (SR7). After the erase all blocks end, erase results can be checked by reading bit 5 (SRS) of the status register. For details, refer to the section where the status register is detailed. qBlock Erase Command (2016/D016) By writing the command code “2016” in the first bus cycle and the confirmation command code “D016” and the blobk address in the second bus cycle that follows, the block erase (erase and erase verify) operation starts for the block address of the flash memory to be specified. Whether the block erase operation is completed can be confirmed ____ by reading the status register or the RY/BY Status Flag of flash memory control register. At the same time the block erase opera- tion starts, the read status register mode is automatically entered, so that the contents of the status register can be read out. The status register bit 7 (SR7) is set to “0” at the same time the block erase operation starts and is returned to “1” upon completion of the block erase operation. In this case, the read status register mode remains active until the read array command (FF16) is writ- ten. ____ The RY/BY Status Flag is “0” during block erase operation and “1” when the block erase operation is completed as is the status reg- ister bit 7. After the block erase ends, erase results can be checked by read- ing bit 5 (SRS) of the status register. For details, refer to the section where the status register is detailed. Fig. 61 Erase flowchart Write 2016 2016/D016 Block address Erase completed (Read comand “FF16” write) NO YES Start Write SR5 = 0 ? Erase error YES NO 2016:Erase all blocks command D016:Block erase command SR7 = 1 ? or RY/BY = 1 ? Status register read |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |