  AN1756 Datasheet HTML 1Page - STMicroelectronics AN1756 Datasheet HTML 2Page - STMicroelectronics AN1756 Datasheet HTML 3Page - STMicroelectronics AN1756 Datasheet HTML 4Page - STMicroelectronics AN1756 Datasheet HTML 5Page - STMicroelectronics AN1756 Datasheet HTML 6Page - STMicroelectronics AN1756 Datasheet HTML 7Page - STMicroelectronics AN1756 Datasheet HTML 8Page - STMicroelectronics AN1756 Datasheet HTML 9Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 10 page
background image
AN1756
High-frequency tube lamp ballast applications
3/10
1
High-frequency tube lamp ballast applications
Basically, a HF-TL ballast converts the 50-60 Hz AC Line input or a DC voltage to a high
frequency output, usually in the range of 25-125 kHz. A rectifier block and a DC to high
frequency inverter usually make up a ballast (please refer to 1 in Section 4: References).
Voltage fed series resonant half bridge inverters are currently used for fluorescent lamps.
This topology allows to easily operate in Zero Voltage Switching (ZVS) resonant mode,
reducing the transistor switching losses and the electromagnetic interference (please refer
to 2 in Section 4: References).
The half bridge of the inverter can be controlled in different ways with different ICs:
Half-bridge controller like, for example, the L6574.
Figure 1.
Typical topology with a half-bridge controller
Half-bridge driver like, for example, the L6384 + some kind of control.
Figure 2.
Typical topology with a half-bridge driver
What is the difference between a half-bridge driver and a half-bridge controller?
A driver is “just” able to drive the floating (high side) transistor of a symmetric half bridge
inverter, from a Pulse Width Modulation (PWM) signal. The controller also includes some
form of oscillator, usually tunable by using a few external components (resistor, capacitor).
Varying the switching frequency is the mainly used control principle. This allows the current
in the lamp, and therefore the output power to be modulated (please refer to 2 in Section 4:
References). So the lamp can be dimmed and input voltage variations can be compensated.
To know more about high frequency tube lamp ballast applications, please refer to 2 in
Section 4: References.



Html Pages

1 2 3 4 5 6 7 8 9 10


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com