| 전자부품 데이터시트 검색엔진 |
|
LSM303AGRTR 데이터시트(PDF) 22 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
LSM303AGRTR 데이터시트(HTML) 22 Page - STMicroelectronics |
|
22 / 68 page ![]() Functionality LSM303AGR 22/68 DocID027765 Rev 5 4.1.2 Magnetometer offset cancellation The offset cancellation is the result of performing a set and reset in the magnetic sensor. The offset cancellation technique is defined as follows: where Hn and Hn-1 are two consecutive magnetic field measurements, one after a set pulse, the other after a reset pulse. Considering a magnetic offset (Hoff), the two magnetic field measurements are: Set: Hn = H + Hoff Reset: Hn-1 = –H + Hoff The offset is cancelled according the offset cancellation technique: In the LSM303AGR the offset cancellation is enabled by setting the bit OFF_CANC = 1 in CFG_REG_B_M (61h). If the offset cancellation is disabled, a set of the magnetic sensor is performed anyway. The set pulse frequency can be configured by setting the Set_FREQ bit in CFG_REG_B_M (61h). 4.1.3 Magnetometer interrupt In the LSM303AGR the magnetometer interrupt signal generation is based on the comparison between data and a programmable threshold. To enable the interrupt function, in INT_CTRL_REG_M register (63h) the "IEN" bit must be set to '1'. In the LSM303AGR the user can select the axis/axes in which the interrupt function can be enabled. In order to do this, the XIEN, YIEN, and ZIEN bits in INT_CTRL_REG_M (63h) need be set properly. The threshold value can be programmed by setting the INT_THS_L_REG_M (65h) and INT_THS_H_REG_M (66h) registers. The threshold is expressed in absolute value as a 15-bit unsigned number. The threshold has the same sensitivity as the magnetic data. When magnetic data exceeds the positive or the negative threshold, the interrupt signal is generated and the information about the type of interrupt is stored in the INT_SOURCE_REG_M (64h) register. In particular, when magnetic data exceeds the positive threshold the P_TH_S_axis bit is set to '1', while if data exceeds the negative threshold the N_TH_S_axis bit is set to '1'. If magnetic data lay between the positive and the negative thresholds, no interrupt signal is released. Hout Hn Hn1 – – 2 --------------------------- = Hout Hn Hn1 – – 2 --------------------------- 2H Hoff H – off ++ 2 --------------------------------------------- H == = |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |