6 / 10 page ![]() 6 Rev:A Date: 11/20/03 SP6681 High Efficiency Boost Charge Pump Regulator © Copyright 2002 Sipex Corporation 4) The Clock Phase Control accepts the clock and mode control generated by the Clock Manager and the Charge Pump Switch Configuration Control. This block then provides several clock phases going to the Drivers block. 5) The V OUT Control regulates the Clock Phase Control to ensure V OUT is regulated to 5.0V. 6) The Drivers block drives the clock phase information to the gates of the large pump transistors. 7) The Charge Pump Switch block contains the large transistors that transfer charge to the fly and load capacitors. In normal operation of the device V IN is connected between +2.7 and 5.5V. Refer to Figure 2 for a typical application circuit. When no clock is present (CLK is floating or near ground) the device is in shutdown and the output is connected to the input. This shutdown feature will work either in start up or after the device is pumping. Once a clock is present, the band gap is activated, but only if V IN > 2.3V. Otherwise the device remains in shutdown mode. Once the reference voltage is stable, the device begins the pumping operation. If V IN < 3.70V, the device is configured as a doubler. However, as the output reaches 5.0V, the doubler action is truncated. If V IN is above 3.70V, the device is reconfigured and multiplies the input by a factor of 1.5. This mode reduces the current drawn from the supply and hence increases the power efficiency. As the output reaches 5.0V, the charge transfer to the load capacitor is truncated. APPLICATION INFORMATION Refer to Figure 3 for a typical SIM card application circuit with the SP6681. Oscillator Control The external clock frequency required to drive the internal charge pump oscillator is 32.768kHz (nominal) at the CLK pin. When there is no clock signal present at the CLK pin, the SP6681 device is in a low-power shutdown mode. C/4 and Cx8 are two control lines for the internal charge pump oscillator. When the C/4 control line is forced to a logic high and the Cx8 control line is at a low, the internal charge pump oscillator is set to 8.192kHz. When both the C/4 and Cx8 control lines are at a logic low, the internal charge pump oscillator is set to the input clock signal, 32.768kHz. When the C/4 control line is forced to a logic high, the internal charge pump oscillator is set to 262.14kHz. Figure 2. Typical Application for the SP6681 CF1P VIN CF1N GND SP6681 5 3 2 1 4 CIN = 4.7µF COUT = 2.2µF VOUT CF1 = 2.2µF C/4 Cx8 Frequency Control Inputs CF2N CF2P CLK 10 9 8 7 6 CF2 = 2.2µF Input Clock 2.7V to 5.5V 5.0V |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |