19 / 42 page ![]() ams Datasheet Page 19 [v1-01] 2016-Feb-17 Document Feedback AS5171 − Register Description Figure 22: Output Transfer Function The breakpoint BP sets the discontinuity point where the output jumps from one clamping level to the other. It is strongly recommended to set the breakpoint at the maximum distance from the start and stop position (T1 and T2). To handle the case of a full turn, a hysteresis function across the breakpoint can be used to avoid sudden jumps between the lower and upper clamping level. Figure 23: Hysteresis Setting The hysteresis LSB is based on the core resolution (14-bit). HYST Hysteresis LSBs 00 0 01 56 10 91 11 137 Upper failure band Lower failure band Max out CLMPH CLMPL OT2 OT1 T1 T2 BGPD BVPU Upper clamping band Lower clamping band BP Electrical range Mechanical range Mechanical angle Measured angle |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|