| 전자부품 데이터시트 검색엔진 |
|
MCP39F521 데이터시트(PDF) 41 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP39F521 데이터시트(HTML) 41 Page - Microchip Technology |
|
41 / 52 page ![]() 2015 Microchip Technology Inc. DS20005442A-page 41 MCP39F521 8.7 Temperature Compensation The MCP39F521 measures the indication of the temperature sensor and uses the value to compensate the temperature variation of the shunt resistance and the frequency of the internal RC oscillator. The same formula applies for Line Frequency, Current RMS, Active Power and Reactive Power. The temperature compensation coefficient depends on the 16-bit signed integer value of the corresponding compensation register. EQUATION 8-10: When calibrating the temperature, the effect of the compensation coefficients is minimal. The coefficients need to be tuned when the difference between the calibration temperature and the device temperature is significant. It is recommended to use the default values as starting points. 8.8 Retrieving Factory Default Calibration Values After user calibration and a Save to Flash command has been issued, it is possible to retrieve the factory default calibration values. This can be done by writing 0xA5A5 to the Calibration Register Delimiter, issuing a Save to Flash , and then resetting the part. This procedure will retrieve all factory default calibration values and will remain in this state until calibration has been performed again, and a Save to Flash command has been issued. yx 1 c T T CAL – + = Where: x = Uncompensated Output (corresponding to Line Frequency, Current RMS, Active Power and Reactive Power) y = Compensated Output c = Temperature Compensation Coefficient (depending on the shunt's Temperature Coefficient of Resistance or on the internal RC oscillator temperature frequency drift). There are three registers: one for Line Frequency compensation, one for Current compensation, and one for power compensation (Active and Reactive) T = Thermistor Voltage (in 10-bit ADC units) TCAL = Ambient Temperature Reference Voltage. It should be set at the beginning of the calibration procedure, by reading the thermistor voltage and writing its value to the ambient temperature reference voltage register. M = 26 (for Line Frequency compensation) = 27 (for Current, Active Power and Reactive Power) c TemperatureCompensation Register 2 M ----------------------------------------------------------------------------------------------- = |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |