25 / 42 page ![]() 2016 Microchip Technology Inc. DS20005571A-page 25 MIC45116 • Inadequate ripple at the feedback voltage due to the small ESR of the output capacitors. The output voltage ripple is fed into the FB pin through a feed-forward capacitor, CFF in this situation, as shown in Figure 5-3. The typical CFF value is between 1 nF and 100 nF. EQUATION 5-11: With the feed-forward capacitor, the feedback voltage ripple is very close to the output voltage ripple. FIGURE 5-3: Inadequate Ripple at FB. • Virtually no ripple at the FB pin voltage due to the very low ESR of the output capacitors, such is the case with ceramic output capacitors. In this situation, the VFB ripple waveform needs to be generated by injecting suitable signal. A series RC network between the SW pin and FB pin, RINJ and CINJ as shown in Figure 5-4 injects a square-wave current waveform into the FB pin, which, by means of integration across the capacitor (CFF), generates an appropriate sawtooth FB ripple waveform. FIGURE 5-4: External Ripple Injection Circuit at FB. The injected ripple is calculated via: EQUATION 5-12: EQUATION 5-13: In Equation 5-13 and Equation 5-14, it is assumed that the time constant associated with CFF must be much greater than the switching period: EQUATION 5-14: If the voltage divider resistors RFB1 and RFB2 are in the kΩ range, a CFF of 1 nF to 100 nF can easily satisfy the large time constant requirements. 5.5 Thermal Measurements and Safe Operating Area (SOA) Measuring the IC’s case temperature is recommended to ensure it is within its operating limits. Although this might seem like a very elementary task, it is easy to get erroneous results. The most common mistake is to use the standard thermal couple that comes with a thermal meter. This thermal couple wire gauge is large, typically 22 gauge, and behaves like a heatsink, resulting in a lower case measurement. Two methods of temperature measurement are using a smaller thermal couple wire or an infrared thermometer. If a thermal couple wire is used, it must be constructed of 36-gauge wire or higher (smaller wire size) to minimize the wire heat-sinking effect. In addition, the thermal couple tip must be covered in either thermal grease or thermal glue to make sure that the thermal couple junction is making good contact with the case of the IC. Omega brand thermal couple (5SC-TT-K-36-36) is adequate for most applications. V FB PP ESR COUT I LPP = V OUT FB PGND MIC45116 R FB1 R FB2 C FF C OUT ESR VOUT FB SW PGND MIC45116 R FB1 R FB2 C FF C OUT ESR C INJ R INJ V FB PP V IN K div D 1 D – 1 f SW ----------------- = Where: VIN Power stage input voltage D Duty cycle fSW Switching frequency τ (RFB1//RFB2//RINJ) x CFF K div R FB1//RFB2 R INJ R FB1//RFB2 + ----------------------------------------------- = Where: RINJ 20 kΩ 1 f SW ----------------- T --- =1 « |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |