Back Button N5393D Datasheet HTML 11Page - Keysight Technologies N5393D Datasheet HTML 12Page - Keysight Technologies N5393D Datasheet HTML 13Page - Keysight Technologies N5393D Datasheet HTML 14Page - Keysight Technologies N5393D Datasheet HTML 15Page - Keysight Technologies N5393D Datasheet HTML 16Page - Keysight Technologies N5393D Datasheet HTML 17Page - Keysight Technologies N5393D Datasheet HTML 18Page - Keysight Technologies N5393D Datasheet HTML 19Page - Keysight Technologies Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 25 page
background image
15 | Keysight | N5393D PCI Express® 3.0 (Gen3) Software for Infiniium Oscilloscopes - Data Sheet
Figure 20. Configuring the type of receiver test calibration to perform.
Figure 21. In the HTML test report the N5393D generates the appropriate graphical summary for
each calibration parameter it configures. This gives you a traceable reference for how the tool
setup and the calibration can save time when de-bugging the RX test setup.
The N5393D utilizes the PCI SIG’s
own Seasim simulation software to
determine the target signal impairments
and communicates those parameters
to the instruments configured as part
of the receiver test setup. The Keysight
DSA90000 series oscilloscope is used to
capture traces from the JBERT system
setup, and that information is used by
Seasim to set the calibration values of the
bit error ratio tester setup.
The N5393D utilizes the PCI SIG’s
own Seasim simulation software to
determine the target signal impairments
and communicates those parameters
to the instruments configured as part
of the receiver test setup. The Keysight
DSA90000 series oscilloscope is used to
capture traces from the JBERT system
setup, and that information is used by
Seasim to set the calibration values of the
bit error ratio tester setup.
The N5393D option 004 is provided
to help automate the most rigorous
step in receive testing, the calibration
step. Once the equipment is calibrated,
the actual receiver stress test can be
performed manually or by using additional
automation tools provided by Keysight
and its partners. The N5393C-4FP
covers automates only the calibration
step. You can also reference the Keysight
application note on PCIe 3.0 BASE spec
receiver testing at: http://literature.cdn.
keysight.com/litweb/5990-6599EN.pdf
for additional information.
Receiver Stressed Eye Calibration (Continued)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com