| 전자부품 데이터시트 검색엔진 |
|
DPS310 데이터시트(PDF) 6 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
DPS310 데이터시트(HTML) 6 Page - Infineon Technologies AG |
|
6 / 41 page ![]() 2.2 Block Diagram Figure 2 3 Specifications 3.1 Operating Range The following operating conditions must not be exceeded in order to ensure correct operation of the device. All parameters specified in the following sections refer to these operating conditions, unless noted otherwise. Table 3 Operating Range Parameter Symbol Values Unit Note / Test Condition Min. Typ. Max. Pressure Pa 300 1200 hPa Temperature Ta -40 85 °C Supply voltage VDD 1.7 3.6 V Supply voltage IO VDDIO 1.2 3.6 V Supply voltage ramp-up time tvddup 0.001 5 ms Time for supply voltage to reach 90% of final value. Solder drift1) 0.8 hPa Minimum solder height 50um. Long term stability ±1 hPa Depending on environmental conditions. 1 Effects of solder drift can be eliminated by one point calibration. See AN487. DPS310 - Digital Pressure Sensor Digital Barometric Pressure Sensor for Portable Devices Specifications 6 V1.0 2016-09-05 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|