16 / 28 page ![]() Page 16 ams Datasheet Document Feedback [v2-00] 2016-Jun-01 AS1370 − Application Information Junction Temperature Under operating conditions, the maximum junction temperature should not exceed 125°C. Regulating the maximum junction temperature requires knowledge of the heat path from junction to case ΘJC [°C/W] fixed by the IC manufacturer, and adjustment of the case to ambient heat path ΘCA [°C/W] by manipulation of the PCB copper area adjacent to the IC position. Figure 17: Steady State Heat Flow Equivalent Circuit Total Thermal Path Resistance (junction-to-ambient) is determined by: θJA = θJC + θCS + θSA [ºC/W] Junction Temperature is determined by: TJ = PD(MAX) × θJA + TAMB [ºC] Junction TJ Package TC PCB TS Ambient TA RθJC RθCS RθSA RθJA (EQ6) (EQ7) |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|