| 전자부품 데이터시트 검색엔진 |
|
L99MD01 데이터시트(PDF) 9 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99MD01 데이터시트(HTML) 9 Page - STMicroelectronics |
|
9 / 54 page ![]() L99MD01 Detailed description Doc ID 17242 Rev 6 9/54 2.9 Temperature warning and thermal shutdown If the junction temperature rises above TjTW ON a temperature warning flag is set and is detectable via the SPI. If the junction temperature increases above the second threshold TjSD ON, the thermal shutdown bit is set and power DMOS transistors of all output stages are switched off to protect the device. Temperature warning flag and thermal shutdown bits are latched. In order to reactivate the output stages, the junction temperature must decrease below TjSD ON and the thermal shutdown bit has to be cleared by the microcontroller. 2.10 VS, VS2, VSA, VSB monitoring VS undervoltage: Status bit is set. All outputs and SMPS are switched off. The microcontroller needs to clear the status bits to reactivate the drivers and SMPS. VS overvoltage: Status bit is set. All outputs are switched off (default). The microcontroller needs to clear the status bits to reactivate the drivers Can be deactivated via SPI. VSA undervoltage: Status bit is set. Out 1 to Out 8 are switched off. The microcontroller needs to clear the status bits to reactivate the drivers. VSB undervoltage: Status bit is set. Out 1 to Out 8 are switched off. The microcontroller needs to clear the status bits to reactivate the drivers. VS2 undervoltage: Status bit is set. Only if SPMS is active. The microcontroller needs to clear the status bits to reactivate SMPS VS2 overvoltage: Status bit is set. SMPS is switched off (default). The microcontroller needs to clear the status bits to reactivate SMPS. If the VS2 recovery bit is set, and the VS2 voltage falls below the threshold, the SMPS goes in active mode and the status bit is cleared. Table 2. VS, VS2, VSA, VSB monitoring ‘typ SMPS Out x VS undervoltage 5.7 V Status + off Status + off VS overvoltage 22.0 V X Status + (off or mask) VSA undervoltage 5.7 V X Status + off VSB undervoltage 5.7 V X Status + off VS2 undervoltage VS + 1.5V Status X VS2 overvoltage 35.0 V Status + (off or (off+ recovery)) |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |