| 전자부품 데이터시트 검색엔진 |
|
LPC47M182 데이터시트(PDF) 67 Page - SMSC Corporation |
|
|
|||||||||||||||||||||||||||||
LPC47M182 데이터시트(HTML) 67 Page - SMSC Corporation |
|
67 / 223 page ![]() Advanced I/O Controller with Motherboard GLUE Logic Datasheet SMSC LPC47M182 67 Revision 1.8 SMSC/Non-SMSC Register Sets (02-24-05) DATASHEET Table 6.21 - Skip Bit vs. Read Deleted Data Command RESULTS SK BIT VALUE DATA ADDRESS MARK TYPE ENCOUNTERED SECTOR READ? CM BIT OF ST2 SET? DESCRIPTION OF RESULTS 0 0 1 1 Normal Data Deleted Data Normal Data Deleted Data Yes Yes No Yes Yes No Yes No Address not incremented. Next sector not searched for. Normal termination. Normal termination. Sector not read (“skipped”). Normal termination. 6.13 Read A Track This command is similar to the Read Data command except that the entire data field is read continuously from each of the sectors of a track. Immediately after encountering a pulse on the nINDEX pin, the FDC starts to read all data fields on the track as continuous blocks of data without regard to logical sector numbers. If the FDC finds an error in the ID or DATA CRC check bytes, it continues to read data from the track and sets the appropriate error bits at the end of the command. The FDC compares the ID information read from each sector with the specified value in the command and sets the ND flag of Status Register 1 to a “1” if there no comparison. Multi-track or skip operations are not allowed with this command. The MT and SK bits (bits D7 and D5 of the first command byte respectively) should always be set to “0”. This command terminates when the EOT specified number of sectors has not been read. If the FDC does not find an ID Address Mark on the diskette after the second occurrence of a pulse on the nINDEX pin, then it sets the IC code in Status Register 0 to “01” (abnormal termination), sets the MA bit in Status Register 1 to “1”, and terminates the command. Table 6.22 - Result Phase Table MT HEAD FINAL SECTOR TRANSFERRED TO ID INFORMATION AT RESULT PHASE HOST C H R N 0 0 Less than EOT NC NC R + 1 NC Equal to EOT C + 1 NC 01 NC 1 Less than EOT NC NC R + 1 NC Equal to EOT C + 1 NC 01 NC 1 0 Less than EOT NC NC R + 1 NC Equal to EOT NC LSB 01 NC 1 Less than EOT NC NC R + 1 NC Equal to EOT C + 1 LSB 01 NC NC: No Change, the same value as the one at the beginning of command execution. LSB: Least Significant Bit, the LSB of H is complemented. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |