| 전자부품 데이터시트 검색엔진 |
|
FS9721_LP1 데이터시트(PDF) 33 Page - Fortune Semiconductor Corp. |
|
|
|||||||||||||||||||||||||||||
FS9721_LP1 데이터시트(HTML) 33 Page - Fortune Semiconductor Corp. |
|
33 / 41 page ![]() FS9721_LP1 Rev. 2.0 34/41 Capacitance measurement is to charge/discharge to measuring capacitance through R22 to form a oscillation, then calculate the cycle of oscillation to get the capacitance value. To adjust R22 can calibrate the value in capacitance measurement. J4 and J6 are mode switches. When doing capacitance measurement, J4 and J6 are close. (In actual application, if the linearity is worse when doing 5.120nF measurement, you can take a consideration of paralleling a proximate 1000pF capacitance in input end of capacitance measurement during design. When doing the measurement, to press REL key and make the value be zero before measuring. The linearity of the smaller measurement in capacitance mode will be better.) 14.18 Frequency Measurement ADP SGND R18 10k R28 1M COM Hz FS9721_LP1 R30 100k J7 J9 PTC 1k C15 10uF Diagram 32 Frequency Measurement 14.19 Triode hFE Testing 16.5k 220k VDDA E C B R30 100K ADP Diagram 33 PNP-type Triode |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|