| 전자부품 데이터시트 검색엔진 |
|
AS8846 데이터시트(PDF) 30 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8846 데이터시트(HTML) 30 Page - ams AG |
|
30 / 35 page ![]() Data Sheet AS8446 Revision 1.8, Date 2005-03-17 Page 30 of 35 Battery Voltage Monitor and Over / Under Voltage Detection The Battery voltage monitor has to deliver an analog voltage Vbat_mon in the 5V range which is proportional to the high voltage supply Vbat (normally VDDH = Vbat). The measurement range of the supply voltage Vbat is programmable via the register R11<2:0> to adapt the AS8446 to different application supply voltages. Programming of the MEASUREMENT RANGE of Vbat (programmed by register R11<2:0> à VBAT_RANGE) PARAMETER Programming Register R11 SYMBOL MIN MAX UNIT NOTE R11= 0 à VBAT_RANGE = 5 Vbatmax1 20 V R11= 1 à VBAT_RANGE = 8 Vbatmax2 32 V R11= 2 à VBAT_RANGE = 10 Vbatmax3 40 V R11= 3 à VBAT_RANGE = 15 Vbatmax4 60 V Programmable Measurement Voltage Ranges of Vbat R11= 4 à VBAT_RANGE = 20 Vbatmax5 80 V (1) Note (1): The programmable value of VBAT_RANGE determines the max. value of Vbat measurable by the voltage monitor (condition: Vbat / VBAT_RANGE < 4 V). Note (2): VBAT must not exceed the specified abs. Max. ratings (see Table 3) PARAMETER SYMBOL MIN MAX UNIT NOTE Tolerance of the division factor ∆VBAT_RANGE - 6 + 6 % Tolerance of the programmed over voltage threshold ∆Vovervolt -10 +10 % Tolerance of the programmed ounder voltage threshold ∆Vundervolt -10 +10 % a) Programming of the OVER VOLTAGE detection level of Vbat (programmed by register R12<2:0> à OVER_VOLT and R11<2:0> à VBAT_RANGE) Remark: The maximum over voltage limit of Vbat for safe functionality of AS8446 is limited to Vbat < 30 V and must be respected by appropriate programming. Programmable steps of OVER_VOLT = 0.25 V * VBAT_RANGE = (1.25 or 2.0 or 2.5 or 3.75 or 5.0 ) V OVER_VOLT = 0.25 V * VBAT_RANGE * (R12 + 9) = 11.25 V ... 80 V During an over voltage situation the write access to the Three Wire Interface is blocked and the driver is switched off. b) Programming of the UNDER VOLTAGE detection level of Vbat (programmed by register R13<2:0> à UNDER_VOLT and R11<2:0> à VBAT_RANGE) Remark: The minimium Vbat for full functionality of AS8446 is limited to Vbat > 6.5 V (except for Low-battery- mode reduced functionality is still given between 6V and 6.5V, see Table 4 Operating Conditions). Programmable steps of UNDER_VOLT = 0.25 V * VBAT_RANGE = (1.25 or 2.0 or 2.5 or 3.75 or 5.0 ) V UNDER_VOLT = 0.25 V * VBAT_RANGE * (R13 + 1) = 1.25 V ... 40 V |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |