35 / 66 page ![]() DS12448 Rev 3 35/66 L99LD02 Serial peripheral interface (ST SPI standard) 64 5.3.2 Device application registers The Device Application Registers are all registers accessible using OpCode ‘00’, ‘01’ and ‘10’. An access to an unused address will not lead to any error. Any data read from an unused address is not defined. 5.4 Protocol failure detection To realize a protocol which fulfills certain failsafe requirements, a basic set of failure detection mechanisms is implemented. 5.4.1 Clock monitor During communication (CSN low to high phase) a clock monitor counts the valid SCK clock edges. If the SCK edges do not correlate with the SPI Data Length, an SPIE is reported with the next command and the current communication is rejected. By accessing the Device Information Registers (OpCode = ‘11’), the Clock Monitor is set to a minimum of 16 SCK edges plus a multiple of 8 (e.g. 16, 24, 32). Providing no SCK edge during a CSN low to high phase is not recognized as an SPIE. 5.4.2 SCK polarity (CPOL) check To detect wrong polarity access on SCK, the internal clock monitor is used. Providing first a negative edge on SCK during communication (CSN low to high phase) or a positive edge at last will lead to an SPI Error being reported in the next communication and the current data is rejected. 5.4.3 SCK phase (CPHA) check To verify that the SCK phase of the SPI master is set correctly a special Device Information Register is implemented. By reading this register the data must be 55H. In case AAH is read, the CPHA setting of the SPI master is wrong and a proper communication cannot be guaranteed. 5.4.4 CSN timeout By pulling CSN low, the SDO is set active and leaves the tri-state condition. To ensure communication between other SPI devices within the same bus even in case of CSN stuck at low, a CSN timeout is implemented. By pulling CSN low, an internal timer is started. After the timer end is reached, the current communication is rejected and the SDO is set to tri- state condition. This error is not reported in any specific status register. 5.4.5 Data stuck SDI stuck at GND As a command with all data bits set to ‘0’ and OpCode ‘00’ on address b’000000 cannot be distinguished from an SDI stuck-at-GND error, this command is not allowed. In case |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |