| 전자부품 데이터시트 검색엔진 |
|
VSC880TY 데이터시트(PDF) 11 Page - Vitesse Semiconductor Corporation |
|
|
|||||||||||||||||||||||||||||
VSC880TY 데이터시트(HTML) 11 Page - Vitesse Semiconductor Corporation |
|
11 / 28 page ![]() VITESSE SEMICONDUCTOR CORPORATION Data Sheet VSC880 High Performance 16x16 Serial Crosspoint Switch G52191-0, Rev 4.2 Page 11 01/05/01 © VITESSE SEMICONDUCTOR CORPORATION • 741 Calle Plano • Camarillo, CA 93012 Tel: (800) VITESSE • FAX: (805) 987-5896 • Email: prodinfo@vitesse.com Internet: www.vitesse.com Figure 4: Switch Configuration Interface Functional Timing (CEN=0) The switch configuration data for each port is as follows: F0[3:0] = FI[port9], FI[port8], FI[port1], FI[port0] F1[3:0] = FI[port11], FI[port10], FI[port3], FI[port2] F2[3:0] = FI[port13], FI[port12], FI[port5], FI[port4] F3[3:0] = FI[port15], FI[port14], FI[port7], FI[port6] C0[15:0] = Port9[3:0], Port8[3:0], Port1[3:0], Port0[3:0] C1[15:0] = Port11[3:0], Port10[3:0], Port3[3:0], Port2[3:0] C2[15:0] = Port13[3:0], Port12[3:0], Port5[3:0], Port4[3:0] C3[15:0] = Port15[3:0], Port14[3:0], Port7[3:0], Port6[3:0] Where FI[portN] is the Force IDLE bit for port N and PortN[3:0] is the input port number to be connected to output port N. 1.7 Built-in Self-Test The switch has built-in self-test logic that can be used to verify the high-speed circuitry as well as the switch matrix while operating at full speed. The built-in self-test mode is enabled by setting the built-in self-test enable (BSTEN) signal HIGH. If the signal BSTLPBK is set HIGH and TESTEN is set LOW, it loops all 16 serial outputs back to the Data Recovery Unit (DRU) at the serial inputs. An internal Pseudo Random Bit Sequence (PRBS) generator connected to the switch matrix at port 0. The random data is sent to port 0, passed through the switch matrix, looped back through the serial interface and returned to the data comparator. If this data matches the correct pattern, BSTPASS is set HIGH. By configuring port 0 to connect to other ports (ports 1 through 15) through the switch matrix using the parallel configuration interface, the rest of the serial channels (one port at a time) can be tested in turn. For example, port 0 can be connected to port 1 by configuring the switch matrix. The PRBS generator transmits the random data through port 0 to port 1, and the random data is then looped back from port 1 to port 0 and the data comparator. To test all 16 ports, the user will need to configure the switch matrix 16 times to test all ports. REFCLK DATA[15:0] WEN C0 C1 C3 C2 Switch updated in this cycle FI[3:0] F0 F1 F3 F2 CCLK Min. of 5 Cycles |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |