8 / 13 page ![]() Electrical specifications L9914 8/13 DS4742 Rev 7 Figure 4. Setpoint voltage vs. L terminal signal 2.5 Diagnostic Tj -35 °C to +150 °C unless otherwise specified. 2.5.1 Fault The following table lists the conditions that cause the fault driver to function (L terminal now switching between 0 V and VLSAT). To prevent L flicker, specific faults are required to be present for TDELAY seconds before the fault driver is activated. This delay is indicated in the following table. Table 7. Diagnostic Symbol Parameter Test conditions Min. Typ. Max. Unit VOV Overvoltage(1) - 16.5 - 22 V TDELAY Fault indication delay time - 0.935 1.1 1.265 s 1. When the VGO voltage overcomes this value the MFDC is cancelled. Table 8. Fault Conditions Delay 1. Key-on (RVC PWM signal acknowledgement) No 2. Phase voltage < VP2 and VGO < setpoint Yes |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|