31 / 79 page ![]() Data Sheet ADF4377 THEORY OF OPERATION analog.com Rev. 0 | 31 of 79 because REG0010 triggers the VCO calibration and loading of all double buffers and, therefore, must be the last SPI register written to. The SINGLE_INSTRUCTION bit disables streaming mode when it is set to 1. When SINGLE_INSTRUCTION is set to 0, streaming mode is enabled. Block Power Down Control The power down control bits of the ADF4377 reside in REG0019 and REG001A. The PD_ALL, PD_RDET, PD_CLKOUT1, and PD_CLKOUT2 bits may be programmed independently. The PD_CLK, PD_CALDAC, PD_RDIV, PD_NDIV, PD_VCO, PD_LD, and PD_PFDCP bits must be set to the same state at all times. The only time this group is allowed to be set to 1 is when a full power-down ambient temperature measurement is performed (see Table 23). In all other cases, this bit grouping must be set to 0. Figure 79. Serial Interface, Recommended Streaming Mode (SINGLE_INSTRUCTION = 0) with Decrementing Registers (ADDRESS_ASCENCION = 0) |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|