35 / 75 page ![]() NXP Semiconductors FXPS7115D4 Digital absolute pressure sensor, 40 kPa to 115 kPa Bit 7 6 5 4 3 2 1 0 Symbol TEMP[7:0] Reset 0 0 0 0 0 0 0 0 Access R R R R R R R R Table 45. TEMPERATURE - temperature register (address 0Eh) bit allocation 7.7.4 DEVLOCK_WR - lock register writes register (address 10h) The lock register writes register is a read/write register that contains the ENDINIT bit and reset control bits. Bit 7 6 5 4 3 2 1 0 Symbol ENDINIT reserved reserved reserved SUP_ERR_DIS reserved RESET[1:0] Factory default 0 0 0 0 0 0 0 0 Access R/W R/W R/W R/W R/W R/W R/W R/W Table 46. DEVLOCK_WR - lock register writes register (address 10h) bit allocation Bit Symbol Description 7 ENDINIT The ENDINIT bit is a control bit used to indicate that the user has completed all device and system level initialization tests. Once the ENDINIT bit is set, writes to all writable register bits are inhibited except for the DEVLOCK_WR register. Once set, the ENDINIT bit can only be cleared by a device reset. When ENDINIT is set, the following occurs: • An error detection is enabled for all user writable registers. The error detection code is continuously calculated on the user writable registers and verified against a previously calculated error detection code. • Self-test is disabled and inhibited. • Register writes are inhibited except for the RESET[1:0] bits in the DEVLOCK_WR register. 3 SUP_ERR_DIS The supply error disable bit allows the user to disable reporting of the supply errors in the SPI status fields. In SPI Mode: • 0: No Response until the supply monitor timer expires. The Sensor Data Field Error Code is transmitted for one response after the supply monitor timer expires. All supply errors are cleared by a read of the DEVSTAT1 register through any communication interface or on a data transmission that includes the error in the status field if and only if the timer has reached zero. • 1: No Responses occur if the timer is non-zero. The error is cleared when the timer reaches zero and normal transmissions resume. In I2C Mode (0 or 1): • No response until the supply monitor timer expires. • All supply errors are cleared by a read of the DEVSTAT1 register. 1 to 0 RESET[1:0] To reset the device, three consecutive register write operations must be performed in the order shown in Table 48, or the device will not reset.[1] Table 47. DEVLOCK_WR - lock register writes register (address 10h) bit description [1] After POR and/or soft reset, see Section 7.5.5 for initialization sequence. FXPS7115D4 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2022. All rights reserved. Product data sheet Rev. 6 — 6 June 2022 35 / 75 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |