52 / 81 page ![]() Note: 1. KeyId specifies the OTP zone block to be used in the TempKey calculation. Table 5-71. Output Response - GenDig OTP Name Size Description Response 1 byte 0x00 - If successful. Error code - If the command fails. Notes: Flag Bits 1. TempKey.Valid flag will be set to 1 if successful, otherwise it is 0. 2. TempKey.GenDigData will be set to 0. Table 5-72. TempKey Calculation - GenDig OTP 32 bytes 1 byte 1 byte 2 bytes 1 byte 2 bytes 25 bytes 32 bytes OTP Zone Block Opcode = 0x15 Mode = 0x00 KeyID[0:1] = 0x0[block] 0x00 SN[8] = Varies by vendor SN[0:1] = 0x01 0x23 All Zeros TempKey.Value 5.3.4.3 GenDig - Data Data from the Data zone slots can be included in the GenDig calculation. Data are always included in 32-byte blocks and only the lowest block of a slot is included in the GenDig calculation. The Nonce command must be run prior to the first GenDig command to load a value into TempKey. If the slot requires a random nonce, then the data must be generated by the Nonce command versus passing it into the device. Subsequent GenDig commands will use the value from the previous GenDig operation. If a slot is set for NoMAC, then it is not allowed to use the output of this GenDig in a MAC command. If multiple GenDigs are run, if any slot has NoMAC set, then the output in TempKey cannot be used in executing a MAC command. Table 5-73. Input Parameters - GenDig Data Opcode (1 Byte) Mode (1 Byte) KeyID(1) (2 Bytes) Data (0 or 4 Bytes) Description 0x15 0x02 0x00 0[Slot] — Use data from slot # in the calculation. 0x00 0[Slot] 4 bytes Use data from slot # in the calculation and other data when using a NoMAC key slot Note: 1. KeyId specifies the Data zone slot to be used in the TempKey calculation. Only the lowest 32 bytes will be used. Table 5-74. Output Response - GenDig Data Name Size Description Response 1 byte 0x00 - If successful. Error code - If the command fails. Notes: Flag Bits 1. TempKey.Valid flag will be set to 1 if successful, otherwise it is 0. 2. TempKey.GenDigData will be set to 1 indicating a DataZone slot was used in the calculation. 3. TempKey.KeyID will set to the slot specified in the command. 4. TempKey.NoMacFlag will be set to 0 if the MAC command is allowed and 1 if it is not. ATECC608A-TNGLoRaWAN Device Commands © 2020 Microchip Technology Inc. Complete Datasheet DS40002154B-page 52 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |